Abstract

This study of 106 patients who had end-to-end anastomoses (EEA) performed by 26 surgeons in 11 hospitals reports the operative and postoperative complications of using the EEA stapling device. The complications are probably exaggerated, because this study involves the initial experiences of many surgeons. The 106 patients included 78 patients with colon anastomoses, 3 with small intestinal anastomoses, and 25 with gastric anastomoses. The mortality rate included two patients (1.9%) with low rectal anastomoses who died of problems associated with the EEA stapler. The anastomotic morbidity rate included 9 operative complications (9%), which were corrected at operation, and 12 postoperative complications (11%), which included leaks (4), fistula (4), and stenosis (4). Intra-abdominal abscess occurred in 3 and wound infections in 19 patients (18%). The EEA stapler requires practice and specific skills for its safe use. The EEA stapler makes a reliable, inverted anastomosis and can be used successfully throughout the gastrointestinal tract.

摘要

本研究对11家医院的26位外科医生为106例患者实施的端端吻合术(EEA)进行了报道,内容包括使用EEA吻合器的手术及术后并发症情况。这些并发症可能被夸大了,因为本研究涉及众多外科医生的初始经验。106例患者中,78例行结肠吻合术,3例行小肠吻合术,25例行胃吻合术。死亡率方面,有2例(1.9%)低位直肠吻合患者死于与EEA吻合器相关的问题。吻合口发病情况包括9例(9%)术中并发症,均在手术中得到纠正,以及12例(11%)术后并发症,其中包括渗漏4例、瘘管4例和狭窄4例。3例发生腹腔内脓肿,19例(18%)出现伤口感染。EEA吻合器的安全使用需要实践和特定技巧。EEA吻合器能做出可靠的倒置吻合,可成功应用于整个胃肠道。