Wyss C R, Bennett T D, Scher A M
Am J Physiol. 1982 Jun;242(6):H1118-21. doi: 10.1152/ajpheart.1982.242.6.H1118.
In dogs with atrioventricular block and implanted ascending aortic flow probes, cardiac output can be controlled on each beta. The procedure is implemented through on-line use of a digital computer. The algorithm has three steps: 1) aortic flow is measured and integrated to give stroke volume; 2) at the end of ejection, the program computes how long the current beat must be to keep cardiac output at a target level; and 3) the ventricle is stimulated at the proper time. Cardiac output can be controlled over a range of 60-110% of normal in a resting dog. This range can be expanded by combining hemorrhage or volume infusion with the control procedure.
对于植入了升主动脉血流探头的房室传导阻滞犬,可在每个β波上控制心输出量。该过程通过数字计算机的在线使用来实现。该算法有三个步骤:1)测量主动脉血流并进行积分以得出每搏量;2)在射血末期,程序计算当前心跳必须持续多长时间才能将心输出量维持在目标水平;3)在适当的时间刺激心室。在静息犬中,心输出量可在正常水平的60%-110%范围内得到控制。通过将出血或容量输注与控制程序相结合,这个范围可以扩大。