Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.

作者信息

Sahn D J, DeMaria A, Kisslo J, Weyman A

出版信息

Circulation. 1978 Dec;58(6):1072-83. doi: 10.1161/01.cir.58.6.1072.

Abstract

Four hundred M-mode echocardiographic surveys were distributed to determine interobserver variability in M-mode echocardiographic measurements. This was done with a view toward examining the need and determining the criteria for standardization of measurement. Each survey consisted of five M-mode echocardiograms with a calibration marker, measured by the survey participants anonymously. The echoes were judged of adequate quality for measurement of structures. Seventy-six of the 400 (19%) were returned, allowing comparison of interobserver variability as well as examination of the measurement criteria which were used. Mean measurements and percent uncertainty were derived for each structure for each criterion of measurement. For example, for the aorta, 33% of examiners measured the aorta as an outer/inner or leading edge dimension, and 20% measured it as an outer/outer dimension. The percent uncertainty for the measurement (1.97 SD divided by the mean) showed a mean of 13.8% for the 25 packets of five echoes measured using the former criteria and 24.2% using the latter criteria. For ventricular chamber and cavity measurements, almost one-half of the examiners used the peak of the QRS and one-half of the examiners used the onset of the QRS for determining end-diastole. Estimates of the percent of measurement uncertainty for the septum, posterior wall and left ventricular cavity dimension in this study were 10--25%. They were much higher (40--70%) for the right ventricular cavity and right ventricular anterior wall. The survey shows significant interobserver and interlaboratory variation in measurement when examining the same echoes and indicates a need for ongoing education, quality control and standardization of measurement criteria. Recommendations for new criteria for measurement of M-mode echocardiograms are offered.

摘要

分发了400份M型超声心动图测量报告,以确定M型超声心动图测量中观察者间的变异性。这样做是为了检查标准化测量的必要性并确定其标准。每份报告包含五张带有校准标记的M型超声心动图,由参与报告的人员匿名测量。这些回声被判定质量足以用于结构测量。400份报告中有76份(19%)被返还,这使得能够比较观察者间的变异性,并检查所使用的测量标准。针对每个测量标准,得出了每个结构的平均测量值和不确定度百分比。例如,对于主动脉,33%的检查者将主动脉测量为外/内或前缘尺寸,20%的检查者将其测量为外/外尺寸。使用前一种标准测量的25组五张回声的测量不确定度百分比(1.97倍标准差除以平均值)平均为13.8%,使用后一种标准时为24.2%。对于心室腔测量,几乎一半的检查者使用QRS波峰,另一半检查者使用QRS波起始点来确定舒张末期。本研究中,室间隔、后壁和左心室腔尺寸测量不确定度百分比的估计值为10% - 25%。右心室腔和右心室前壁的不确定度百分比则高得多(40% - 70%)。该调查显示,在检查相同回声时,观察者间和实验室间的测量存在显著差异,表明需要持续开展教育、进行质量控制并规范测量标准。文中还提供了关于M型超声心动图测量新标准的建议。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验