Norris J L, Cleasby G W
Ann Ophthalmol. 1982 Apr;14(4):371-2.
Pars plana endoscopy was used to guide removal of a large nonmagnetic intraocular foreign body from an eye with corneal scarring and irregularity of such a degree the view through the operating microscope was not adequate to permit such surgery.
采用玻璃体平坦部内镜引导,从一只存在角膜瘢痕且瘢痕程度导致手术显微镜视野不佳、不足以进行此类手术的眼睛中取出了一个大型非磁性眼内异物。