Ploysongsang Y, Paré J A, Macklem P T
Am Rev Respir Dis. 1982 Sep;126(3):526-9. doi: 10.1164/arrd.1982.126.3.526.
We measured regional breath sound intensities (Ib) by a microphone amplifier system in 8 subjects with emphysema. We also measured regional white noise transmissions (Tn) from the same areas in all subjects. The recorded areas were 5, 10, 15, and 20 cm from the apex of the lung just lateral to the right anterior midclavicular line. Xenon ventilation indexes (xenon tidal raw counts, an index of total regional ventilation; xenon equilibration raw counts, an index of ventilating lung volume; xenon ventilation per unit volume (Vr), an index of ventilation per unit volume) were also recorded from the same areas. The Ib, Tn, Ib/Tn (an index of sound generation), and xenon ventilation indexes were all expressed as a fraction of the mean value of all four recorded areas. The Ib and Ib/Tn correlated best with the xenon tidal raw counts, correlated well with the xenon equilibration raw counts, and correlated poorly with Vr. We conclude that Ib and Ib/Tn can be used to quantify regional ventilation in subjects with emphysema.
我们使用麦克风放大系统测量了8名肺气肿患者的局部呼吸音强度(Ib)。我们还测量了所有受试者相同区域的局部白噪声传输(Tn)。记录区域为右前锁骨中线外侧距肺尖5、10、15和20厘米处。还从相同区域记录了氙气通气指标(氙气潮气量原始计数,总局部通气指标;氙气平衡原始计数,通气肺容积指标;单位体积氙气通气量(Vr),单位体积通气指标)。Ib、Tn、Ib/Tn(声音产生指标)和氙气通气指标均表示为所有四个记录区域平均值的分数。Ib和Ib/Tn与氙气潮气量原始计数相关性最佳,与氙气平衡原始计数相关性良好,与Vr相关性较差。我们得出结论,Ib和Ib/Tn可用于量化肺气肿患者的局部通气。