Suhre F B, Corrao P A, Glover A, Malanoski A J
J Assoc Off Anal Chem. 1982 Nov;65(6):1339-45.
A study was designed to compare the Kjel-Foss automated macro-Kjeldahl method and a block digestion-steam distillation method. The official AOAC Kjeldahl method was used as a reference procedure. Six products with a crude protein range of 10-30% were analyzed by 23 laboratories. Five laboratories analyzed the samples by the official AOAC method, 8 laboratories used the automated Kjel-Foss method, and 11 laboratories used the block digestion with steam distillation method. Standard deviations for each product and each method for both repeatability and reproducibility are given. The block digestion-steam distillation method has been adopted official first action.
设计了一项研究来比较凯耶尔-福斯自动常量凯氏定氮法和批量消化-蒸汽蒸馏法。官方AOAC凯氏定氮法用作参考程序。23个实验室对六种粗蛋白含量范围为10%-30%的产品进行了分析。五个实验室采用官方AOAC方法分析样品,八个实验室使用凯耶尔-福斯自动法,11个实验室使用批量消化与蒸汽蒸馏法。给出了每种产品以及每种方法的重复性和再现性的标准偏差。批量消化-蒸汽蒸馏法已被官方首次采用。