Suppr超能文献

肉及肉制品中粗蛋白测定的燃烧法:协同研究

Combustion method for determination of crude protein in meat and meat products: collaborative study.

作者信息

King-Brink M, Sebranek J G

机构信息

Iowa State University, Department of Animal Science, Ames 50011.

出版信息

J AOAC Int. 1993 Jul-Aug;76(4):787-93.

PMID:8374325
Abstract

Twelve laboratories participated in a collaborative study to compare a combustion method with the AOAC mercury catalyst Kjeldahl method (928.08) for the determination of crude protein in meat and meat products. Three different combustion instruments were used; consequently, the combustion method for this study is written in generic terms describing the principle, the apparatus specifications, and the performance requirements needed. Fifteen sample pairs were used for the study; each pair consisted of the same commercial meat product from each of 2 different manufacturers. Protein content of all samples ranged from about 10 to 20%. In addition, nicotinic acid and lysine monohydrochloride were used as standards to assess combustion equipment performance. All laboratories and all instruments performed the combustion method satisfactorily on the basis of results for the standards. For the meat samples, repeatability standard deviations (Sr) ranged from 0.11 to 0.40 for the Kjeldahl method and from 0.12 to 0.41 for the combustion method; the repeatability relative standard deviations (RSDr) ranged from 0.82 to 2.41% and from 0.60 to 2.23% for the Kjeldahl and combustion methods, respectively. Reproducibility standard deviations (SR) ranged from 0.20 to 0.49 for the Kjeldahl method and from 0.18 to 0.46 for the combustion method, whereas the reproducibility relative standard deviations (RSDR) ranged from 1.59 to 2.84% for the Kjeldahl method and from 1.32 to 3.35% for the combustion method. Overall grand means were 15.59% protein for the Kjeldahl method and 15.75% protein for the combustion method. The combustion method was adopted first action by AOAC International.

摘要

十二个实验室参与了一项协作研究,以比较一种燃烧法与美国官方分析化学师协会(AOAC)汞催化剂凯氏定氮法(928.08)用于测定肉类和肉类产品中的粗蛋白。使用了三种不同的燃烧仪器;因此,本研究中的燃烧法是以通用术语编写的,描述了原理、仪器规格以及所需的性能要求。该研究使用了十五对样品;每对样品由来自两家不同制造商的相同商业肉类产品组成。所有样品的蛋白质含量范围约为10%至20%。此外,使用烟酸和赖氨酸盐酸盐作为标准来评估燃烧设备的性能。根据标准结果,所有实验室和所有仪器都令人满意地完成了燃烧法。对于肉类样品,凯氏定氮法的重复性标准偏差(Sr)范围为0.11至0.40,燃烧法的重复性标准偏差(Sr)范围为0.12至0.41;凯氏定氮法和燃烧法的重复性相对标准偏差(RSDr)分别范围为0.82%至2.41%和0.60%至2.23%。凯氏定氮法的再现性标准偏差(SR)范围为0.20至0.49,燃烧法的再现性标准偏差(SR)范围为0.18至0.46,而凯氏定氮法的再现性相对标准偏差(RSDR)范围为1.59%至2.84%,燃烧法的再现性相对标准偏差(RSDR)范围为1.32%至3.35%。凯氏定氮法的总体平均值为蛋白质含量15.59%,燃烧法的总体平均值为蛋白质含量15.75%。燃烧法被美国官方分析化学师协会国际组织首次采用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验