Chayen J, Gilbert D M, Robertson W R, Bitensky L, Besser G M
J Immunoassay. 1980;1(1):1-13. doi: 10.1080/01971528008055772.
A cytochemical section-bioassay of thyrotropin has been developed which retains the sensitivity of the earlier segment-assay (10(-4) microunits/ml) and allows a considerable increase in the rate at which these within-animal bioassays can be done. The index of precision (n=23) was 0.11 +/- 0.06; intra-assay variation was 1.3%; inter-assay variation was 10.9 +/- 6%. Fiducial limits (p = 0.95) ranged from 65-150% to 78-127%. The system is also capable of detecting thyroid-stimulating immunoglobulins.
已开发出一种促甲状腺激素的细胞化学切片生物测定法,该方法保留了早期片段测定法的灵敏度(10^(-4)微单位/毫升),并能大幅提高这些动物体内生物测定的完成速度。精密度指数(n = 23)为0.11±0.06;批内变异为1.3%;批间变异为10.9±6%。置信限(p = 0.95)范围为65 - 150%至78 - 127%。该系统还能够检测甲状腺刺激免疫球蛋白。