Suppr超能文献

左心室心内膜下微区的血流与高能磷酸盐

Blood flow and high-energy phosphates in microregions of left ventricular subendocardium.

作者信息

Kleinert H D, Weiss H R

出版信息

Am J Physiol. 1981 May;240(5):H804-10. doi: 10.1152/ajpheart.1981.240.5.H804.

Abstract

Blood flow and high-energy phosphate (HEP) content were determined simultaneously in multiple microregions of left ventricular subendocardium in 29 normal anesthetized open-chest rabbits by use of a new micromethod to determine whether a direct linear relationship existed between these parameters. Tissue samples weighed 1-2 mg. ATP and creatine phosphate (CP) content were quantitated in quick-frozen hearts by fluorometry at sites where tissue perfusion was measured by H2 clearance by use of bare-tipped platinum electrodes. A series of validation studies were conducted to ensure that 1) no significant damage to the tissue surrounding the electrode occurred during the period of experimentation and 2) no significant loss of biochemical constituents had occurred due to labile processes during freezing or storage of the tissue. Blood flow, ATP, and CP values averaged 79.1 +/- 24.1 (SD) ml.min-1.100 g-1, 4.9 +/- 1.3 mumol/g tissue, and 8.0 +/- 3.0 mumol/g tissue, respectively, and are similar to those reported in studies using larger tissue samples. Correlation between the heterogeneous distribution of tissue perfusion and HEP revealed no direct linear relationship between these parameters in the normal unstressed rabbit subendocardium.

摘要

通过一种新的微量方法,在29只正常麻醉开胸兔的左心室心内膜下多个微区同时测定血流和高能磷酸(HEP)含量,以确定这些参数之间是否存在直接线性关系。组织样本重1 - 2毫克。在通过使用裸尖铂电极的氢气清除法测量组织灌注的部位,通过荧光法对速冻心脏中的三磷酸腺苷(ATP)和磷酸肌酸(CP)含量进行定量。进行了一系列验证研究,以确保:1)在实验期间电极周围的组织没有受到明显损伤;2)在组织冷冻或储存期间,由于不稳定过程,生化成分没有明显损失。血流、ATP和CP值分别平均为79.1±24.1(标准差)毫升·分钟-1·100克-1、4.9±1.3微摩尔/克组织和8.0±3.0微摩尔/克组织,与使用较大组织样本的研究报告的值相似。在正常未受应激的兔心内膜下,组织灌注的不均匀分布与HEP之间的相关性表明这些参数之间不存在直接线性关系。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验