Agrawal K P
Respir Physiol. 1981 Jan;43(1):23-30. doi: 10.1016/0034-5687(81)90085-2.
A differential body plethysmograph was developed for direct determination of specific airway conductance (SGaw) in intact conscious guinea pigs, breathing spontaneously at room temperature. Box pressure changes were measured as differences between chest volume (delta V1) and air volume respired at atmospheric pressure (delta V2) and fed to X-axis of an X-Y recorder. Airflow signal was fed to its Y-axis. A loop was formed. The slope of the rising limb of this loop provided the ratio of airflow change during transition from expiration to inspiration (delta V2) and corresponding delta (V1-V2), which is practically free from "temperature-humidity artifact" because of minimal lung volume change over this period. This ratio delta V2/delta (V1-V2), when divided by barometric pressure after subtracting water vapour pressure at body temperature (PB-PH2O), gave the value of SGaw at normal end expiration, i.e., at functional residual capacity (FRC). In 42 male guinea pigs, used in this study, SGaw was found to be 0.48 +/- 0.06 sec-1 (cm H2O)-1, comparable to the value obtained by using available data regarding lung resistance and FRC. It was independent of body weight (250-750 g). Histamine induced fall in SGaw was determined by comparing the slopes of the rising limbs of the X-Y loops obtained after and before exposure to histamine aerosol. Log-normal plots of histamine base (W/V%) and SGaw, as % of control, were used to assess airway reactivity.
开发了一种差动式体容积描记器,用于直接测定完整清醒豚鼠在室温下自主呼吸时的比气道传导率(SGaw)。箱内压力变化通过测量胸容积(ΔV1)与大气压下呼出的空气容积(ΔV2)之间的差值来确定,并输入到X-Y记录仪的X轴。气流信号输入到其Y轴,形成一个环路。该环路上升支的斜率提供了从呼气到吸气过渡期间气流变化(ΔV2)与相应的Δ(V1-V2)的比值,由于在此期间肺容积变化极小,该比值实际上不受“温度-湿度伪影”的影响。该比值ΔV2/Δ(V1-V2),在减去体温下的水蒸气压力(PB-PH2O)后除以大气压,得到正常呼气末即功能残气量(FRC)时的SGaw值。在本研究中使用的42只雄性豚鼠中,发现SGaw为0.48±0.06秒-1(厘米水柱)-1,与使用关于肺阻力和FRC的现有数据获得的值相当。它与体重(250-750克)无关。通过比较暴露于组胺气雾剂前后获得的X-Y环路上升支的斜率来确定组胺引起的SGaw下降。使用组胺碱(重量/体积%)和SGaw(作为对照的百分比)的对数正态图来评估气道反应性。