Determination of the dibucaine number of serum permits the differentiation of genetically normal serum cholinesterase from the dibucaine-resistant variant. This communication presents a method for the rapid determination of dibucaine numbers on an automated analyzer that is in widespread use. With this method, dibucaine numbers for seventy-eight normal, four heterozygous, and five dibucaine-resistant sera were 79 +/- 3,60 +/- 10, and 20 +/- 3 (+/- SD), respectively. There was good agreement between the original method and the automated method with a correlation coefficient of 0.98 on split sample comparison of thirty-eight normal, four heterozygous, and five abnormal sera. Advantages of this method over the original include the lack of need for advance preparation and that it can provide results within one-half hour of phlebotomy.

摘要

血清丁卡因值的测定有助于区分基因正常的血清胆碱酯酶和丁卡因抵抗变异体。本文介绍了一种在广泛使用的自动分析仪上快速测定丁卡因值的方法。采用该方法,78份正常血清、4份杂合血清和5份丁卡因抵抗血清的丁卡因值分别为79±3、60±10和20±3(±标准差)。在对38份正常血清、4份杂合血清和5份异常血清进行的分割样本比较中,原方法与自动方法之间具有良好的一致性,相关系数为0.98。该方法相对于原方法的优点包括无需提前准备,且能在采血后半小时内给出结果。