Threshold measurements with a Präcitronic KH 70 bone vibrator were carried out on 25 young, otologically normal subjects (50 ears) in the frequency range between 125 Hz and 8 000 Hz. The vibrator was applied to the human mastoid as well as to the forehead. The non-test ear was masked. Equivalent threshold force levels were determined on an artificial mastoid type B & K 4930. Between 125 Hz and 2 000 Hz, the equivalent threshold force levels for mastoid placement decrease steadily by about 13.5 dB/octave, they then increase again by about 10 dB and remain constant between 4 000 Hz and 8 000 Hz. The equivalent threshold force levels for forehead application were found to be higher by about 11 dB in the whole frequency range.

摘要

使用Präcitronic KH 70骨振动器对25名听力正常的年轻受试者(50只耳朵)在125赫兹至8000赫兹的频率范围内进行阈值测量。将振动器应用于人体乳突以及前额。对非测试耳进行掩蔽。在B&K 4930型人工乳突上测定等效阈值力水平。在125赫兹至2000赫兹之间,乳突放置的等效阈值力水平以约13.5分贝/倍频程的速度稳步下降,然后再次上升约10分贝,并在4000赫兹至8000赫兹之间保持恒定。发现在整个频率范围内,前额应用的等效阈值力水平大约高11分贝。