Hitchings R A, Wheeler C A
Br J Ophthalmol. 1980 Apr;64(4):232-9. doi: 10.1136/bjo.64.4.232.
A prospective study was carried out over a 3-year period on patients with one normotensive eye and one eye with ocular hypertension. A greater variability inthe responses to visual field testing was apparent in the hypertensive eye, but only on comparison of serial visual fields. Analysis of the stereo disc photographs demonstrated larger cup to disc ratios in the hypertensive eye without changes in the nerve fibre layer to equate with the visual field response. Stero disc photography is a quick and simple method of recording changes in the optic disc and should be considered in the follow-up of ocular hypertensive patients.
一项为期3年的前瞻性研究对一只眼血压正常而另一只眼患有高眼压症的患者进行。在高血压眼,视野测试反应的变异性更大,但仅在系列视野比较时才明显。立体视盘照片分析显示高血压眼的杯盘比更大,而神经纤维层没有变化,这与视野反应相符。立体视盘摄影是一种记录视盘变化的快速简单方法,在高眼压症患者的随访中应予以考虑。