Guerret M, Lavene D, Kiechel J R
J Pharm Sci. 1980 Oct;69(10):1191-3. doi: 10.1002/jps.2600691019.
An electron-capture GLC method was developed for measuring pindolol in human plasma and urine. The unchanged drug was extracted with benzene from alkalinized plasma or urine using propranolol as the internal standard. Both compounds subsequently were back-extracted into 0.1 M HCl and then into benzene. After evaporation of the organic phase, the compounds were derivatized with trifluoroacetylimidazole to form the trifluoroacetyl ester of pindolol and propranolol. These derivatives then were analyzed by electron-capture GLC. The method allowed the measurement of concentrations as low as 1 ng of pindolol/ml of plasma and was applied successfully to determinations of plasma levels in humans after oral administraton of a single 10-mg dose of pindolol.
已开发出一种电子捕获气相色谱法,用于测定人血浆和尿液中的吲哚洛尔。以普萘洛尔为内标,用苯从碱化的血浆或尿液中提取未变化的药物。随后将两种化合物反萃取到0.1 M盐酸中,再萃取到苯中。有机相蒸发后,用三氟乙酰咪唑将化合物衍生化,形成吲哚洛尔和普萘洛尔的三氟乙酰酯。然后通过电子捕获气相色谱法分析这些衍生物。该方法可测定低至1 ng吲哚洛尔/毫升血浆的浓度,并成功应用于单次口服10 mg吲哚洛尔后人体血浆水平的测定。