The stimulation threshold behaviour in long-term cardiac pacing is presented for a material of 45 myocardial electrodes. The initial stimulation threshold was measured in 25 cases and the mean value was 1.5 +/- 0.7 mA. The follow-up period was from 17 to 99 months (mean 50 months) and during that time 63 threshold measurements were made. The mean chronic stimulation threshold was 2.2 +/- 0.7 mA. It was not dependent on the aetiology or type of the conduction defect. There was no relationship between the initial and chronic stimulation threshold. In the region of the left ventricular apex, the chronic stimulation threshold was higher than in the anterior wall of the right ventricle. The long-term stimulation threshold was significantly higher in the cases of enlarged heart and in the age group less than or equal to 50 years than in those with a heart of normal size and in the age group greater than or equal to 70 years.
本文介绍了45个心肌电极材料在长期心脏起搏中的刺激阈值行为。在25例患者中测量了初始刺激阈值,平均值为1.5±0.7 mA。随访期为17至99个月(平均50个月),在此期间进行了63次阈值测量。慢性刺激阈值的平均值为2.2±0.7 mA。它不依赖于传导缺陷的病因或类型。初始刺激阈值与慢性刺激阈值之间没有关系。在左心室心尖区域,慢性刺激阈值高于右心室前壁。心脏扩大的患者和年龄小于或等于50岁的患者的长期刺激阈值明显高于心脏大小正常的患者和年龄大于或等于70岁的患者。