Zeschke G, Schönfelder G, Nitschkoff S
Acta Biol Med Ger. 1978;37(7):1025-35.
The conditions under which flow measurements using the ultrasonic doppler technique can be successfully carried out at the Aorta ascendens in chronical experiments were studied in 25 normal rabbits. Pressure necroses of the vascular wall at agar-agar-gel coupling arise only if the implanted pick-off with its inner diameter is less than the outer diameter of the aorta + about 10%. The ultrasonic intensity permissible in a chronic experiment is only about 0.3 W/cm2. With the 13 implantations the animals were maximally usable for 86.6 days; 70% of them were killed in good health. In a beat-to-beat analysis were determined: (1) heart rate, (2) discharge duration, (3) maximal rate of discharge, (4) acceleration of blood flow, (5) deceleration of blood flow, (6) beat volume, (7) contraction force of the left ventricle, and (8) discharge resistance. The control recordings obtained over several months are on the average within normal limits.
在25只正常家兔身上研究了在慢性实验中使用超声多普勒技术在升主动脉成功进行血流测量的条件。只有当植入的传感器内径小于主动脉外径+约10%时,在琼脂 - 琼脂 - 凝胶耦合处血管壁才会出现压力坏死。慢性实验中允许的超声强度仅约为0.3W/cm²。在13次植入实验中,动物最长可使用86.6天;其中70%的动物在健康状态下被处死。在逐搏分析中测定了:(1)心率,(2)射血持续时间,(3)最大射血速率,(4)血流加速度,(5)血流减速度,(6)每搏量,(7)左心室收缩力,以及(8)射血阻力。数月来获得的对照记录平均在正常范围内。