Questionnaire survey on the use of dental X-ray film and equipment among general practitioners in the Swedish Public Dental Health Service.

作者信息

Svenson B, Petersson A

机构信息

Department of Oral Radiology, Postgraduate Dental Education Center, Orebro, Sweden.

出版信息

Acta Odontol Scand. 1995 Aug;53(4):230-5. doi: 10.3109/00016359509005978.

Abstract

A questionnaire was sent to all clinics in the Public Dental Health Service in Orebro County in 1989 and 1993. The survey comprised questions about X-ray film and developing technique. The questionnaire of 1993 was accompanied by questions on the type of dental X-ray film and collimator each dentist used, altogether 175 dentists. The results showed that Kodak Ektaspeed dental X-ray film was used by 53% of the dentists in 1993. The mean number of months to the expiry date for all film packages irrespective of film type increased from a mean of 7.5 months to a mean of 13 months from 1989 to 1993. Only 11% of the Ektaspeed film packages in 1989 had a base plus fog < or = 0.25, whereas the figure in 1993 was 30%. Rectangular collimation adjusted to the size-2 film (31 mm x 41 mm) was used by 36% of the dentists in 1993. In 1993, 88% of the clinics used automatic processing, and in 85% of the clinics both automatic and manual processing was used. The processing time and temperature varied greatly for both automatic and manual processing. The results indicate that film and developing procedures in Swedish general dental practice are not always in accordance with the recommendations and guidelines of the Swedish National Radiation Protection Institute (SSI) and that attempts should be made to improve dentists' behavior with regard to radiation safety. A major dose reduction would be achievable without jeopardizing diagnosis if the regulations of the SSI were followed by using the fastest available film and optimum developing procedures.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

1989年和1993年,一份调查问卷被寄给了厄勒布鲁县公共牙科保健服务中心的所有诊所。该调查包含有关X光胶片和显影技术的问题。1993年的问卷还附带了关于每位牙医使用的牙科X光胶片类型和准直器的问题,共有175名牙医参与。结果显示,1993年有53%的牙医使用柯达Ektaspeed牙科X光胶片。从1989年到1993年,所有胶片包装(无论胶片类型)距有效期的平均月数从7.5个月增加到了13个月。1989年,只有11%的Ektaspeed胶片包装的片基加灰雾≤0.25,而1993年这一数字为30%。1993年,36%的牙医使用了根据2号胶片(31毫米×41毫米)尺寸调整的矩形准直。1993年,88%的诊所使用自动冲洗,85%的诊所同时使用自动和手动冲洗。自动和手动冲洗的处理时间和温度差异很大。结果表明,瑞典普通牙科实践中的胶片和显影程序并不总是符合瑞典国家辐射防护研究所(SSI)的建议和指南,应该努力改善牙医在辐射安全方面的行为。如果遵循SSI的规定,使用现有最快的胶片和最佳显影程序,在不影响诊断的情况下可实现大幅剂量减少。(摘要截选至250词)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验