Detection of beta-2 transferrin in otorrhea and rhinorrhea in a routine clinical laboratory setting.

作者信息

Normansell D E, Stacy E K, Booker C F, Butler T Z

机构信息

Department of Pathology, University of Virginia Health Sciences Center, Charlottesville 22908, USA.

出版信息

Clin Diagn Lab Immunol. 1994 Jan;1(1):68-70. doi: 10.1128/cdli.1.1.68-70.1994.

Abstract

A simple, straightforward, and rapid method for the detection of beta-2 transferrin in otorrhea and rhinorrhea that can be used in a routine clinical laboratory is described. The beta-2 transferrin was detected by agarose gel electrophoresis of the fluid on Beckman Paragon equipment, followed by pressure transfer to a nitrocellulose membrane and then incubation with enzyme-labeled antitransferrin antibody and substrate. The procedure was fast (3.5 h) and sensitive (detected as little as 1 microgram/ml) and required only 3 microliters of fluid. Beta-2 transferrin was detected in cerebrospinal fluid diluted up to eightfold. No special training or expertise was needed, and all equipment and procedures used are commonly available in a routine clinical laboratory.

摘要

本文描述了一种简单、直接且快速的方法,用于检测耳漏和鼻漏中的β-2转铁蛋白,该方法可在常规临床实验室中使用。通过在贝克曼Paragon设备上对液体进行琼脂糖凝胶电泳来检测β-2转铁蛋白,随后进行压力转移至硝酸纤维素膜,再与酶标记的抗转铁蛋白抗体和底物孵育。该程序快速(3.5小时)且灵敏(最低可检测到1微克/毫升),仅需3微升液体。在稀释至八倍的脑脊液中也能检测到β-2转铁蛋白。无需特殊培训或专业知识,且所使用的所有设备和程序在常规临床实验室中均常见。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2630/368198/9355b5160962/cdli00001-0091-a.jpg

相似文献

1
Detection of beta-2 transferrin in otorrhea and rhinorrhea in a routine clinical laboratory setting.
Clin Diagn Lab Immunol. 1994 Jan;1(1):68-70. doi: 10.1128/cdli.1.1.68-70.1994.
2
Immunoblotting of transferrin in the identification of cerebrospinal fluid otorrhoea and rhinorrhoea.
Ann Clin Biochem. 1992 Mar;29 ( Pt 2):210-3. doi: 10.1177/000456329202900216.
5
Separation of beta2-transferrin by denaturing gel electrophoresis to detect cerebrospinal fluid in ear and nasal fluids.
Clin Chem. 2005 Sep;51(9):1704-10. doi: 10.1373/clinchem.2005.054916. Epub 2005 Jul 14.
9
A new method for the identification of cerebrospinal fluid leakage.
Acta Otolaryngol. 1979 Mar-Apr;87(3-4):366-9. doi: 10.3109/00016487909126434.

引用本文的文献

1
Digital biosensor for human cerebrospinal fluid detection with single-use sensing strips.
J Vac Sci Technol B Nanotechnol Microelectron. 2022 Mar;40(2):023202. doi: 10.1116/6.0001576. Epub 2022 Feb 1.
2
Rapid Diagnostic Test Kit for Point-of-Care Cerebrospinal Fluid Leak Detection.
SLAS Technol. 2020 Feb;25(1):67-74. doi: 10.1177/2472630319877377. Epub 2019 Sep 22.
3
Point-of-Care Cerebrospinal Fluid Detection.
Otolaryngol Head Neck Surg. 2018 Nov;159(5):824-829. doi: 10.1177/0194599818789075. Epub 2018 Jul 24.
4
A new nephelometric assay for beta-trace protein (prostaglandin D synthase) as an indicator of liquorrhoea.
J Neurol Neurosurg Psychiatry. 2001 Sep;71(3):347-51. doi: 10.1136/jnnp.71.3.347.

本文引用的文献