Levallois P, Gauvin D, St-Laurent J, Gingras S, Deadman J E
Centre de Santé Publique de Québec, Ste-Foy, Canada.
Environ Health Perspect. 1995 Sep;103(9):832-7. doi: 10.1289/ehp.95103832.
The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18 adults, mostly white-collar workers, living in different bungalows located 190-240 feet from the line (exposed subjects) was compared to that of 17 adults living in similar residences far away from any transmission line. Each subject carried a Positron meter for 24 hr during 1 workday, which measured 60-Hz electric and magnetic fields every minute. All measurements were carried out in parallel for exposed and unexposed subjects during the same weeks between September and December. During measurements the average loading on the line varied between 600 and 1100 A. The average magnetic field intensity while at home was 4.4 times higher among exposed subjects than unexposed (7.1 versus 1.6 mG, p = 0.0001) and 6.2 times higher when considering only the sleeping period (6.8 versus 1.1 mG, p = 0.0001). Based on the 24-hr measurement, average magnetic field exposure was three times higher among the exposed. Electric field intensity was also higher among the exposed while at home (26.3 versus 14.0 V/m, p = 0.03). Magnetic field intensity among the exposed was positively correlated with the loading on the line (r = 0.8, p = 0.001). Percentage of time above a magnetic field threshold (2 mG or 7.8 mG) was a good indicator to distinguish the two types of exposure.(ABSTRACT TRUNCATED AT 250 WORDS)
本研究的目的是评估一条735千伏输电线路对居住在线路路权边缘的人群所受电场和磁场暴露的影响。将18名居住在距离线路190 - 240英尺(约58 - 73米)不同平房中的成年人(暴露组受试者),其中大多为白领,与17名居住在远离任何输电线路的类似住宅中的成年人的暴露情况进行比较。每位受试者在1个工作日内佩戴正电子测量仪24小时,每分钟测量60赫兹的电场和磁场。在9月至12月的同一周内,对暴露组和未暴露组受试者同时进行了所有测量。测量期间线路的平均负载在600至1100安培之间变化。在家时,暴露组受试者的平均磁场强度比未暴露组高4.4倍(7.1对1.6毫高斯,p = 0.0001),仅考虑睡眠期间则高6.2倍(6.8对1.1毫高斯,p = 0.0001)。基于24小时测量,暴露组的平均磁场暴露高出三倍。在家时暴露组的电场强度也更高(26.3对14.0伏/米,p = 0.03)。暴露组的磁场强度与线路负载呈正相关(r = 0.8,p = 0.001)。高于磁场阈值(2毫高斯或7.8毫高斯)的时间百分比是区分两种暴露类型的良好指标。(摘要截短于250字)