Suzuki T, Kanda T, Kubota S, Imai S, Murata K
College of Medical Care and Technology, Gunma University School of Medicine, Maebashi, Japan.
Chest. 1994 Oct;106(4):1021-4. doi: 10.1378/chest.106.4.1021.
We investigated the usefulness of 24-h Holter monitoring for identification of myocardial involvement in 38 patients with sarcoidosis, including 12 patients with cardiac sarcoidosis, and 58 healthy controls. Ventricular ectopic beats (VEB) > or = 100 beats per day were detected in 8 (67 percent) of 12 patients with cardiac sarcoidosis, in 2 (8 percent) of 26 patients without cardiac sarcoidosis, and in 3 (5 percent) of 58 healthy controls. Holter monitoring was associated with a sensitivity of 67 percent and a specificity of 62 percent for cardiac sarcoidosis in the overall study population. In patients with sarcoidosis, specificity was 80 percent. Lown's grade 4 A and 4 B VEBs were detected in 8 (67 percent) of 12 patients with cardiac sarcoidosis, in 2 (8 percent) of 26 patients with sarcoidosis without cardiac involvement, and in 2 (3 percent) of 58 controls. Holter monitoring was associated with a sensitivity of 67 percent and a specificity of 80 percent for identification of cardiac involvement in patients with systemic sarcoidosis. Our findings suggest that 24-h Holter monitoring provides a convenient and inexpensive means of noninvasive screening for cardiac involvement in generalized sarcoidosis, even in patients and outpatients who are without symptoms.
我们对24小时动态心电图监测在38例结节病患者(包括12例心脏结节病患者)及58例健康对照者中识别心肌受累情况的实用性进行了研究。12例心脏结节病患者中有8例(67%)检测到室性异位搏动(VEB)≥100次/天,26例无心脏结节病的患者中有2例(8%)检测到,58例健康对照者中有3例(5%)检测到。在整个研究人群中,动态心电图监测对心脏结节病的敏感性为67%,特异性为62%。在结节病患者中,特异性为80%。12例心脏结节病患者中有8例(67%)检测到洛恩4A级和4B级室性异位搏动,26例无心脏受累的结节病患者中有2例(8%)检测到,58例对照者中有2例(3%)检测到。动态心电图监测对系统性结节病患者心脏受累识别的敏感性为67%,特异性为80%。我们的研究结果表明,24小时动态心电图监测为全身性结节病患者心脏受累情况提供了一种方便且廉价的无创筛查方法,即使是无症状的患者和门诊患者也是如此。