Suppr超能文献

体外剪切应力介导的人脐静脉内皮细胞上白细胞黏附受体表达的变化。

Shear stress-mediated changes in the expression of leukocyte adhesion receptors on human umbilical vein endothelial cells in vitro.

作者信息

Sampath R, Kukielka G L, Smith C W, Eskin S G, McIntire L V

机构信息

Cox Laboratory for Biomedical Engineering, Rice University, Houston, TX, USA.

出版信息

Ann Biomed Eng. 1995 May-Jun;23(3):247-56. doi: 10.1007/BF02584426.

Abstract

Extensive monocyte recruitment is an early phenomenon associated with the development of atherosclerotic lesions, suggesting an active role for the involvement of adhesion receptors expressed by endothelial cells. In this study we describe the contribution of hemodynamic shear forces in regulating the expression of a few of the monocyte adhesion receptors, including intercellular adhesion molecule (ICAM-1), vascular cell adhesion molecule (VCAM-1), and E-selectin on endothelial cells. A parallel plate flow chamber and recirculating flow loop device was used to expose human umbilical vein endothelial cells (HUVECs) to different levels of shear (2-25 dyn/cm2). Subsequently the cells were analyzed either for shear induced changes in the mRNA levels of adhesion receptors by Northern blot analyses or for changes in the surface expression of ICAM-1 using flow cytometry. Results from the fluorescence analysis showed a transient increase in the surface expression of ICAM-1, 12 hr after exposure to 25 dyn/cm2 shear, returning to basal levels within 24 hr. This was quite different from the time dependent response of ICAM-1 to lipopolysaccharide (LPS), where ICAM-1 expression was maximally induced 18-24 hr post-stimulus. ICAM-1 mRNA level appeared slightly elevated after exposure to shear for 1 hr, compared to basal values, but dropped below basal levels within 6 hr. This biphasic response was seen irrespective of the magnitude of applied shear stress. VCAM-1 mRNA expression, in contrast, decreased below the baseline expression within an hour after onset of flow, and appeared to be considerably down-regulated within 6 hr. After exposure to shear for 24 hr, no increase in mRNA levels could be detected for either molecule, at any shear magnitude. E-selectin mRNA was less responsive to shear stress, especially at the lower magnitudes of shear. After an hour of exposure to flow E-selectin mRNA level appeared slightly reduced compared with control levels, but it remained at this level even after 6 hr of flow. These results indicate that the expression of adhesion receptors is sensitive to local shear stresses in a manner that is molecule specific in the short term even though prolonged exposure to flow results in similar down-regulation for both ICAM-1 and VCAM-1.

摘要

广泛的单核细胞募集是与动脉粥样硬化病变发展相关的早期现象,这表明内皮细胞表达的黏附受体发挥了积极作用。在本研究中,我们描述了血流动力学剪切力在调节一些单核细胞黏附受体表达中的作用,这些受体包括细胞间黏附分子(ICAM-1)、血管细胞黏附分子(VCAM-1)和内皮细胞上的E-选择素。使用平行板流动腔和循环流动环装置将人脐静脉内皮细胞(HUVECs)暴露于不同水平的剪切力(2-25达因/平方厘米)。随后,通过Northern印迹分析检测细胞中黏附受体mRNA水平的剪切诱导变化,或使用流式细胞术分析ICAM-1表面表达的变化。荧光分析结果显示,在暴露于25达因/平方厘米的剪切力12小时后,ICAM-1的表面表达出现短暂增加,并在24小时内恢复到基础水平。这与ICAM-1对脂多糖(LPS)的时间依赖性反应有很大不同,在LPS刺激后18-24小时,ICAM-1的表达被最大程度诱导。与基础值相比,暴露于剪切力1小时后,ICAM-1 mRNA水平略有升高,但在6小时内降至基础水平以下。无论施加的剪切应力大小如何,均观察到这种双相反应。相比之下,VCAM-1 mRNA表达在流动开始后1小时内降至基线表达以下,并且在6小时内似乎被显著下调。在暴露于剪切力24小时后,在任何剪切力大小下,均未检测到这两种分子的mRNA水平增加。E-选择素mRNA对剪切应力的反应较小,尤其是在较低的剪切力水平下。暴露于流动1小时后,E-选择素mRNA水平与对照水平相比略有降低,但即使在流动6小时后仍保持在该水平。这些结果表明,黏附受体的表达对局部剪切应力敏感,在短期内具有分子特异性,尽管长时间暴露于流动会导致ICAM-1和VCAM-1出现类似的下调。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验