Navaratnam V, Mansor S M, Chin L K, Mordi M N, Asokan M, Nair N K
Centre for Drug Research, Universiti Sains Malaysia, Penang.
J Chromatogr B Biomed Appl. 1995 Jul 21;669(2):289-94. doi: 10.1016/0378-4347(94)00109-i.
A selective reproducible high-performance liquid chromatographic assay for the simultaneous quantitative determination of the antimalarial compound artemether (ARM), dihydroartemisinin (DQHS) and artemisinin (QHS), as internal standard, is described. After extraction from plasma, ARM and DQHS were analysed using a Lichrocart/Lichrosphere 100 CN stainless-steel column and a mobile phase of acetonitrile-0.05 M acetic acid (15:85, v/v) adjusted to pH 5.0, and electrochemical detection in the reductive mode. The mean recovery of ARM and DQHS over a concentration range of 30-120 ng/ml was 81.6% and 93.4%, respectively. The within-day coefficients of variation were 0.89-7.01% for ARM and 3.45-8.11% for DQHS. The day-to-day coefficients of variation were 2.06-8.43% and 3.22-6.33%, respectively. The minimum detectable concentration for ARM and DQHS in plasma was 2.5 and 1.25 ng/ml for both compounds. The method was found to be suitable for use in clinical pharmacological studies.
本文描述了一种选择性可重现的高效液相色谱法,用于同时定量测定抗疟化合物蒿甲醚(ARM)、双氢青蒿素(DQHS)和作为内标的青蒿素(QHS)。从血浆中提取后,使用Lichrocart/Lichrosphere 100 CN不锈钢柱和乙腈-0.05 M乙酸(15:85,v/v)的流动相(pH值调至5.0),以还原模式进行电化学检测,分析ARM和DQHS。在30-120 ng/ml的浓度范围内,ARM和DQHS的平均回收率分别为81.6%和93.4%。ARM日内变异系数为0.89-7.01%,DQHS为3.45-8.11%。日间变异系数分别为2.06-8.43%和3.22-6.33%。血浆中ARM和DQHS的最低检测浓度均为2.5和1.25 ng/ml。该方法适用于临床药理学研究。