Pituitary glands of rats, injected with estrogen to increase the prolactin (PRL) storage in secretory granules, were submitted to various extraction procedures for prolactin. Homogenization and centrifugation of pituitary tissue, in Tris-HCl buffer, pH 7.3, yielded a small amount of radioimmunoassayable prolactin, which increased remarkably after extraction in alkaline pH, disruption of granular membranes with Lubrol and specially after treatment with 2.5 mol/l urea. Nb2 lymphoma cell and pigeon crop sac bioassay (BA) revealed higher levels of bioactivity after extraction in Tris buffer, pH 7.3, in comparison to RIA, with BA/RIA ratios of 1.4 and 2.3, respectively. Bioassays of pituitary PRL extracted with Lubrol and alkaline medium, were less effective in quantifying PRL than RIA. Treatment of pituitary homogenates with urea produced the highest levels of PRL by both BA and RIA, with BA/RIA ratios close to 1. The thorough depolymerization of big PRL effected by urea produced the release of monomeric subunits which allows a complete quantification of the total content in the pituitary gland.
给大鼠注射雌激素以增加分泌颗粒中催乳素(PRL)的储存量,然后对其垂体进行各种催乳素提取程序。将垂体组织在pH 7.3的Tris-HCl缓冲液中匀浆并离心,得到少量可通过放射免疫测定的催乳素,在碱性pH下提取、用Lubrol破坏颗粒膜后,尤其是用2.5 mol/l尿素处理后,其含量显著增加。与放射免疫测定(RIA)相比,Nb2淋巴瘤细胞和鸽嗉囊生物测定(BA)显示,在pH 7.3的Tris缓冲液中提取后生物活性水平更高,BA/RIA比值分别为1.4和2.3。用Lubrol和碱性介质提取的垂体PRL的生物测定在定量PRL方面不如RIA有效。用尿素处理垂体匀浆后,通过BA和RIA测得的PRL水平最高,BA/RIA比值接近1。尿素对大PRL的彻底解聚导致单体亚基的释放,从而能够对垂体中的总含量进行完全定量。