Suppr超能文献

Mechanical properties of human round window, basilar and Reissner's membranes.

作者信息

Ishii T, Takayama M, Takahashi Y

机构信息

Department of Otolaryngology, Tokyo Women's Medical College, Japan.

出版信息

Acta Otolaryngol Suppl. 1995;519:78-82. doi: 10.3109/00016489509121875.

Abstract

In order to measure the mechanical strength of small and delicate biological specimens, a microtesting system was developed. We measured the mechanical properties of the round window, basilar and Reissner's membranes taken from the autopsied cases. The testing method was a displacement of the specimen by a force sensor needle until rupture. A load-displacement curve was then drawn and the mechanical value of each specimen was calculated. Reissner's membrane was the weakest, though it showed a measurable strength. From the load-displacement curve of the basilar membrane, it could be displaced by a smaller force than the rupture strength of Reissner's membrane. Speculation about the concept of a negative summating potential in Meniere's disease is therefore theoretically possible from a mechanical point of view.