Abstract

Aluminum ranks as a potentially hazardous agent. Pathologic findings in different organs show that it can accumulate in brain, muscle, liver and bone. Therefore, we investigated whether patients with cementless total hip endoprostheses made out of titanium alloys containing aluminum are at risk. In order to determine the complete aluminum body loading in patients who have had their hip replacement for a long period of time (mean 58 months), we mobilized possible stores of aluminum with desferoxamine (DFO). Electrothermal atomic absorption spectroscopy was used to quantify the level of aluminum in serum and urine before and after DFO treatment. A serum aluminum value of 10 micrograms/l or less is internationally accepted as safe. The average serum aluminum level in this study was 14.2 micrograms/l, which is slightly above the limit, but clearly below those levels which can lead to disease (> 50 micrograms/l). No relevant storage of aluminum was found. This latter finding is more important since chronically elevated aluminum levels lead to cellular deposits, which affect the cellular biochemistry. The values before and after DFO mobilization did not differ substantially, indicating that aluminum in alloys for biomaterials can be regarded as safe as far as the risk of aluminum release in vivo is concerned. Histologic studies of bone from the bone-metal interface also showed no deposits of local aluminum release.

摘要

铝被列为一种潜在的有害物质。不同器官的病理研究结果表明,它可在脑、肌肉、肝脏和骨骼中蓄积。因此,我们调查了使用含铝钛合金制成的非骨水泥型全髋关节假体的患者是否存在风险。为了确定长期(平均58个月)接受髋关节置换术患者体内铝的总负荷量,我们用去铁胺(DFO)调动可能储存的铝。采用电热原子吸收光谱法对DFO治疗前后血清和尿液中的铝含量进行定量。国际上公认血清铝值10微克/升或更低为安全值。本研究中血清铝的平均水平为14.2微克/升,略高于该限值,但明显低于可导致疾病的水平(>50微克/升)。未发现铝的相关蓄积。后一项发现更为重要,因为铝水平长期升高会导致细胞内沉积,进而影响细胞生物化学。DFO调动前后的值没有显著差异,这表明就生物材料合金中铝在体内释放的风险而言,可以认为其是安全的。对骨-金属界面处的骨组织学研究也未显示局部铝释放的沉积。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验