Sotereanos N G, Engh C A, Glassman A H, Macalino G E, Engh C A
Anderson Orthopaedic Research Institute, Arlington, VA, USA.
Clin Orthop Relat Res. 1995 Apr(313):146-53.
Before 1982, the authors performed 177 primary total hip arthroplasties using a single-sized, extensively porous-coated cobalt-chrome femoral prosthesis. The current status of 122 of these arthroplasties is known. Two femoral prostheses have been revised for late symptomatic loosening, 2 for stem fracture, and 1 for infection. From 1982 to 1984, 227 primary arthroplasties were performed using the same stem in multiple sizes. Of these cases, 171 are available for followup. One stem (0.6%) has been revised for symptomatic loosening. Large osteolytic femoral lesions (average size, 8.1 cm2) developed in 3 patients, associated with an unusually large amount of polyethylene wear of their acetabular components. These patients have been treated by exchange of the polyethylene liner within the porous-coated acetabular component and allografting of the osteolytic lesions. The femoral components were not exchanged because osteolysis had not eroded the integrity of the supporting bone-implant interface to a point where loosening occurred. Before 1987, 193 patients with loose femoral components were treated with revision total hip arthroplasty, also using an extensively porous-coated cobalt-chrome femoral stem of similar design. Ten (5.7%) patients have required rerevision of the femoral prosthesis. Six of these 10 rerevisions were performed because of symptomatic loosening. Ninety-three percent of the patients in the primary series had relief of their preoperative pain and have improved functional ability; 94.2% are satisfied with their results. In the revision series, 89.1% of the patients are free of pain and function better than preoperatively, and 89.6% are fully satisfied with their results.(ABSTRACT TRUNCATED AT 250 WORDS)
1982年以前,作者使用单一尺寸、广泛多孔涂层的钴铬合金股骨假体进行了177例初次全髋关节置换术。已知其中122例置换术的当前状况。有2个股骨假体因晚期症状性松动而进行了翻修,2例因柄部骨折,1例因感染。1982年至1984年,使用多种尺寸的同一柄部进行了227例初次置换术。在这些病例中,171例可供随访。有1个柄部(0.6%)因症状性松动而进行了翻修。3例患者出现了大的股骨溶骨病变(平均大小为8.1平方厘米),与其髋臼部件异常大量的聚乙烯磨损有关。这些患者通过在多孔涂层髋臼部件内更换聚乙烯衬垫和对溶骨病变进行同种异体骨移植进行了治疗。未更换股骨部件,因为骨溶解尚未侵蚀支撑骨-植入物界面的完整性至发生松动的程度。1987年以前,193例股骨部件松动的患者接受了翻修全髋关节置换术,同样使用了设计相似的广泛多孔涂层钴铬合金股骨干。10例(5.7%)患者需要对股骨假体进行再次翻修。这10例再次翻修中有6例是因为症状性松动。初次系列中的93%患者术前疼痛得到缓解,功能能力得到改善;94.2%的患者对结果满意。在翻修系列中,89.1%的患者无痛,功能比术前更好,89.6%的患者对结果完全满意。(摘要截断于250字)