Suppr超能文献

长期接受雌激素替代疗法(ERT)的女性的足跟超声检查结果与前臂、脊柱和髋部的骨密度对比。

Heel ultrasound in women after long-term ERT compared with bone densities in the forearm, spine and hip.

作者信息

Naessén T, Mallmin H, Ljunghall S

机构信息

Department of Obstetrics and Gynecology, University Hospital, Uppsala, Sweden.

出版信息

Osteoporos Int. 1995 May;5(3):205-10. doi: 10.1007/BF02106101.

Abstract

To compare heel ultrasound values with bone densities at different measurement sites as determined by single photon absorptiometry (SPA) and dual-energy X-ray absorptiometry (DXA) in long-term users of estrogen replacement therapy (ERT), we analyzed data from 30 users of estradiol implants (mean duration of treatment 16 years) and 32 non-users, comprising 28 complete age-matched pairs. The precision errors in vivo of ultrasound measurements were 0.18%, 1.3% and 1.5% for speed of sound (SOS), broadband ultrasound attenuation (BUA) and stiffness index, respectively. In the controls, ultrasound parameters correlated well with values from SPA and DXA measurements (r = 0.51-0.63, p < 0.004). In long-term users of ERT, however, measurements with ultrasound did not correlate with DXA in the spine and hip (r = 0.01-0.31, NS) but correlated well with SPA in the forearm (r = 0.47-0.66, p < 0.009). Implant users, compared with non-users, had small and just significantly different values when measured by ultrasound (at most 12%, p = 0.03-0.04) but significantly higher bone mineral densities (18%-25%, p = 0.0001-0.01) in the forearm, spine and hip when measured by SPA or DXA. Data indicated that a substantial proportion of long-term users of estrogen may be non-responders concerning the effect of estrogen on bone qualities expressed in heel ultrasound values. In a multivariate regression analysis the effect of increasing age and increasing treatment duration were both negative for the ultrasound parameters.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

为了比较长期接受雌激素替代疗法(ERT)的患者足跟超声值与通过单光子吸收测定法(SPA)和双能X线吸收测定法(DXA)在不同测量部位所测得的骨密度,我们分析了30名雌二醇植入剂使用者(平均治疗时长16年)和32名非使用者的数据,其中包括28对完全年龄匹配的对象。超声测量在体内的精度误差,对于声速(SOS)、宽带超声衰减(BUA)和硬度指数分别为0.18%、1.3%和1.5%。在对照组中,超声参数与SPA和DXA测量值相关性良好(r = 0.51 - 0.63,p < 0.004)。然而,在长期接受ERT的患者中,超声测量与脊柱和髋部的DXA测量值不相关(r = 0.01 - 0.31,无显著性差异),但与前臂的SPA测量值相关性良好(r = 0.47 - 0.66,p < 0.009)。与非使用者相比,植入剂使用者通过超声测量时数值较小且仅有显著差异(最多12%,p = 0.03 - 0.04),但通过SPA或DXA测量时,前臂、脊柱和髋部的骨矿物质密度显著更高(18% - 25%,p = 0.0001 - 0.01)。数据表明,很大一部分长期使用雌激素的患者可能对雌激素对足跟超声值所体现的骨质的影响无反应。在多变量回归分析中,年龄增长和治疗时长增加对超声参数均有负面影响。(摘要截选至250词)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验