Cervical myelography and survey radiography was performed on 12 light breed wobbling foals and a new radiographic measurement method was applied for more accurate diagnosis of cervical vertebral instability. Ratios of stenosis of the spinal canal on survey radiography and myelography using relative values in an individual foal were defined on radiograms of lateral flexed position of mid-cervical region, and coincidence between the ratios and histopathological lesions in the cervical spinal cord was investigated. Five of 6 foals had ratios of stenosis on myelography more than 40% at the intervertebral sites where the most severe histopathological lesions were observed. Four of 6 foals had ratios of stenosis on survey radiography more than 40% at the intervertebral sites where the most severe histopathological lesions were observed. Four of 6 foals had ratios of stenosis on survey radiography more than 40% at the intervertebral sites where the most severe histopathological lesions were observed. False-positive diagnosis of CVI was observed in 1 out of 6 foals without histopathological lesion when both ratios of stenosis on myelography and survey radiography were applied. Although the standard value of 40% should be further investigated, the new radiographic measurement method in this study is very useful in clinical diagnosis of cervical vertebral instability in wobbling foals, and the presence of lesions in the cervical spinal cord and their sites by survey radiography may be estimated more accurately.

摘要

对12匹轻型品种的摇摆驹进行了颈椎脊髓造影和X线平片检查,并应用一种新的X线测量方法更准确地诊断颈椎不稳定。在颈椎中部区域侧屈位的X线片上,使用个体驹的相对值定义了X线平片和脊髓造影上椎管狭窄的比率,并研究了这些比率与颈脊髓组织病理学病变之间的一致性。6匹驹中有5匹在观察到最严重组织病理学病变的椎间部位,脊髓造影上的狭窄比率超过40%。6匹驹中有4匹在观察到最严重组织病理学病变的椎间部位,X线平片上的狭窄比率超过40%。当同时应用脊髓造影和X线平片上的狭窄比率时,6匹无组织病理学病变的驹中有1匹出现了颈椎不稳定的假阳性诊断。尽管40%的标准值有待进一步研究,但本研究中的新X线测量方法在摇摆驹颈椎不稳定的临床诊断中非常有用,并且通过X线平片可以更准确地估计颈脊髓病变的存在及其部位。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验