Perkins A C, Vincent R M, Wastie M L, Denton G W, Amar S, Hardcastle J D
Department of Medical Physics, Queen's Medical Centre, Nottingham, UK.
Nucl Med Commun. 1994 Dec;15(12):981-90. doi: 10.1097/00006231-199412000-00010.
The monoclonal antibody conjugate 111In-B72.3 was the first such antibody-based radiopharmaceutical for tumour detection to be granted a propriety product licence in Europe. However, the optimum activity of 111In for planar and SPET imaging is yet to be established. A baseline study of 20 patients with suspected recurrent colorectal cancer has been carried out to assess any effect of administered activity of radionuclide on image quality and tumour detection. Ten patients were administered 80 MBq 111In-Oncoscint and 10 patients a larger amount of activity, 150 MBq (resulting in effective dose equivalents of 25 and 47 mSv, respectively). Planar, orthogonal SPET and 3D volume-rendered SPET images were obtained and the image quality was assessed. The clinical results were compared with computed tomography (CT) and in selected patients magnetic resonance imaging (MRI). No difference in the overall tumour detection was apparent between the two groups and the use of 150 MBq 111In for planar imaging alone cannot be justified. Orthogonal and 3D SPET imaging was helpful in confirming sites of uptake and may justify the use of the higher administered amount of activity; however, false-positive results raise the need for caution in the interpretation of these images. Volume-rendered 3D images offer an attractive method of displaying antibody data and require further evaluation.
单克隆抗体偶联物¹¹¹In - B72.3是欧洲首个获得专利产品许可的用于肿瘤检测的此类基于抗体的放射性药物。然而,¹¹¹In用于平面和单光子发射计算机断层显像(SPET)成像的最佳活度尚未确定。已对20例疑似复发性结直肠癌患者进行了一项基线研究,以评估放射性核素给药活度对图像质量和肿瘤检测的任何影响。10例患者给予80兆贝可(MBq)¹¹¹In - Oncoscint,10例患者给予更大活度,即150 MBq(有效剂量当量分别为25和47毫希沃特)。获取了平面、正交SPET和三维容积再现SPET图像,并对图像质量进行了评估。将临床结果与计算机断层扫描(CT)以及部分患者的磁共振成像(MRI)进行了比较。两组之间在总体肿瘤检测方面没有明显差异,仅使用150 MBq¹¹¹In进行平面成像并无依据。正交和三维SPET成像有助于确认摄取部位,可能证明使用更高给药活度是合理的;然而,假阳性结果提示在解读这些图像时需要谨慎。容积再现三维图像提供了一种展示抗体数据的有吸引力的方法,需要进一步评估。