Suppr超能文献

肝移植前门静脉系统的评估:相位对比磁共振血管造影的价值

Evaluation of the portal venous system before liver transplantation: value of phase-contrast MR angiography.

作者信息

Nghiem H V, Winter T C, Mountford M C, Mack L A, Yuan C, Coldwell D M, Althaus S J, Carithers R L, McVicar J P, Freeny P C

机构信息

University of Washington, Department of Radiology, Seattle 98195, USA.

出版信息

AJR Am J Roentgenol. 1995 Apr;164(4):871-8. doi: 10.2214/ajr.164.4.7726039.

Abstract

OBJECTIVE

The purpose of this study was to assess the accuracy of phase-contrast MR angiography with gadolinium in evaluating the patency and blood flow direction of the portal venous system; the presence, extent, and type of varices; and the patency of surgical decompressive shunts in patients before liver transplantation. This information is essential in management and care of patients with chronic liver disease and portal hypertension and those who are candidates for liver transplantation.

SUBJECTS AND METHODS

Twenty-four patients with portal venous hypertension were evaluated with phase-contrast MR angiography. Two patients had surgical splenorenal shunts and one had a mesocaval shunt. Phase-contrast angiograms were acquired as a series of two-dimensional sequential coronal sections during breath-holding and after IV administration of gadopentetate dimeglumine. Correlative findings from color flow Doppler sonography, contrast-enhanced CT scanning, and conventional angiography were available in 23, 20, and 10 patients, respectively, and were used as standards. The images from each technique were analyzed independently for patency of and flow direction in the portal vein, splenic vein, superior mesenteric vein, and surgically created shunts, and for detection, distribution, and extent of five variceal groups.

RESULTS

Findings from phase-contrast MR angiography completely agreed with those of sonography, CT scanning, and conventional angiography. The main portal vein was patent in 18 patients, stenosed in one, partially thrombosed in one, and occluded in four. Phase-contrast MR angiography correctly showed hepatofugal flow in three patients and hepatopetal flow in 17 patients. Both the splenic and superior mesenteric veins were patent in 20, partially thrombosed in one, and occluded in three cases. Phase-contrast MR angiograms showed 85% of the variceal groups, and MR rating of variceal size was not significantly different from that of CT rating. Phase-contrast MR angiography correctly showed the patency of all three surgical decompressive shunts.

CONCLUSION

Phase-contrast MR angiography is accurate for evaluating the patency and flow direction of the portal venous system, detecting and determining the distribution and extent of varices, and assessing the patency of surgically created shunts. Therefore, it is a reliable and noninvasive technique that can provide crucial information in the preoperative workup of liver transplant recipients.

摘要

目的

本研究的目的是评估钆增强的相位对比磁共振血管造影术在评估肝移植术前患者门静脉系统的通畅性和血流方向、静脉曲张的存在、范围和类型以及手术减压分流术的通畅性方面的准确性。这些信息对于慢性肝病和门静脉高压患者以及肝移植候选者的管理和护理至关重要。

对象与方法

对24例门静脉高压患者进行了相位对比磁共振血管造影术评估。2例患者有脾肾分流手术史,1例有肠系膜上腔静脉分流手术史。在屏气状态下静脉注射钆喷酸葡胺后,以一系列二维连续冠状面图像获取相位对比血管造影。分别有23例、20例和10例患者可获得彩色多普勒超声、增强CT扫描和传统血管造影的相关结果,并将其作为标准。对每种技术的图像进行独立分析,以评估门静脉、脾静脉、肠系膜上静脉和手术创建的分流的通畅性和血流方向,以及五个静脉曲张组的检测、分布和范围。

结果

相位对比磁共振血管造影的结果与超声、CT扫描和传统血管造影的结果完全一致。18例患者的门静脉主干通畅,1例狭窄,1例部分血栓形成,4例闭塞。相位对比磁共振血管造影正确显示3例患者为肝外血流,17例患者为肝内血流。脾静脉和肠系膜上静脉均通畅20例,部分血栓形成1例,闭塞3例。相位对比磁共振血管造影显示了85%的静脉曲张组,静脉曲张大小的磁共振分级与CT分级无显著差异。相位对比磁共振血管造影正确显示了所有三个手术减压分流的通畅性。

结论

相位对比磁共振血管造影术在评估门静脉系统的通畅性和血流方向、检测和确定静脉曲张分布及范围以及评估手术创建分流的通畅性方面是准确的。因此,它是一种可靠的非侵入性技术,可为肝移植受者的术前检查提供关键信息。