不同大转子位置的生物力学研究。

Biomechanical study of various greater trochanter positions.

作者信息

Iglic A, Antolic V, Srakar F, Kralj-Iglic V, Macek-Lebar A, Brajnik D

机构信息

University Clinical Hospital for Orthopaedics, Ljubljana, Slovenia.

出版信息

Arch Orthop Trauma Surg. 1995;114(2):76-8. doi: 10.1007/BF00422829.

Abstract

A mathematical model was used in order to evaluate the mechanical situation after lateral, medial, distal and proximal displacements of the greater trochanter. It was calculated that lateral displacement may considerably reduce the hip joint contact force, while medial displacement greatly increases it. The influence of proximalization and distalization is much less pronounced. It was further shown that, regarding the postoperative relative hip abductor muscle strength, lateral and distal displacements of the greater trochanter are favourable, while proximal and medial displacements are not.

摘要

为了评估大转子向外侧、内侧、远端和近端移位后的力学情况,使用了一个数学模型。计算结果表明,外侧移位可能会显著降低髋关节接触力,而内侧移位则会使其大幅增加。近端移位和远端移位的影响则不太明显。进一步研究表明,就术后相对髋外展肌力量而言,大转子的外侧和远端移位是有利的,而近端和内侧移位则不然。