Suppr超能文献

佛蒙特-牛津试验网络数据库中的数据质量评估。

An assessment of data quality in the Vermont-Oxford Trials Network database.

作者信息

Horbar J D, Leahy K A

机构信息

Department of Pediatrics, University of Vermont College of Medicine, Burlington, USA.

出版信息

Control Clin Trials. 1995 Feb;16(1):51-61. doi: 10.1016/0197-2456(94)00019-y.

Abstract

The Vermont-Oxford Trials Network is a voluntary collaborative research group of neonatologists that maintains a database for very low birthweight infants (501-1500 g). The database (1) provides core data for randomized trials, (2) serves as a resource for outcomes research in neonatology, and (3) generates quality management reports for participating sites. To assess the reliability of this database and to determine the sources of error, we reviewed 635 medical records chosen at random from among the 4341 eligible infants born at 40 participating data generating sites during an 18-month period beginning January 1, 1990. The estimated frequencies of disagreement between the medical record and database for each of the 10 data items studied and the standard errors of the estimates (in parentheses) were: date of birth 1.3% (0.4), date of admission 2.5% (0.6), date of discharge 8.8% (1.0), birthweight (difference > 50 g) 2.9% (0.6), location of birth (inborn or outborn) 2.1% (0.5), multiple birth 2.2% (0.5), cesarean section 2.5% (0.6), gender 2.1% (0.5), status 28 days after birth 3.4% (0.6), final status 2.9% (0.6). The overall proportions and mean values for items in the database were close to the estimated values based on the random sample of records. There were a total of 247 disagreements between the database and the medical records in the sample. Twenty-three were due to data keying errors. Two hundred twenty-four were due to errors in transcription or interpretation. The rate of data keying errors decreased from over 50 errors per 10,000 fields to less than 15 errors per 10,000 fields when specific quality control procedures, including visual inspection, were instituted. Data keying errors accounted for 13.7% of all disagreements between the database and medical record before improved data entry methods were introduced, and only 3.7% of all errors after they were introduced. We concluded that the Vermont-Oxford Trials Network Database is reliable. Data keying errors have been reduced by the introduction of additional quality control measures. Further reductions in database errors will require measures aimed at minimizing transcription or interpretation errors by individuals completing the data forms.

摘要

佛蒙特-牛津试验网络是一个由新生儿科医生组成的自愿合作研究小组,该小组为极低出生体重婴儿(501 - 1500克)维护一个数据库。该数据库:(1)为随机试验提供核心数据;(2)作为新生儿科结局研究的资源;(3)为参与站点生成质量管理报告。为评估该数据库的可靠性并确定错误来源,我们从1990年1月1日开始的18个月期间内,在40个参与数据生成站点出生的4341名符合条件的婴儿中随机抽取了635份病历进行审查。所研究的10项数据中,病历与数据库之间不一致的估计频率及估计的标准误(括号内)分别为:出生日期1.3%(0.4),入院日期2.5%(0.6),出院日期8.8%(1.0),出生体重(差异>50克)2.9%(0.6),出生地点(院内或院外)2.1%(0.5),多胎2.2%(0.5),剖宫产2.5%(0.6),性别2.1%(0.5),出生后28天状态3.4%(0.6),最终状态2.9%(0.6)。数据库中各项的总体比例和平均值与基于随机抽取病历的估计值接近。样本中数据库与病历之间共有247处不一致。23处是由于数据录入错误。224处是由于转录或解释错误。当制定包括目视检查在内的特定质量控制程序后,数据录入错误率从每10000个字段超过50处错误降至每10000个字段少于15处错误。在引入改进的数据录入方法之前,数据录入错误占数据库与病历之间所有不一致情况的13.7%,引入之后仅占所有错误的3.7%。我们得出结论,佛蒙特-牛津试验网络数据库是可靠的。通过引入额外的质量控制措施,数据录入错误已减少。要进一步减少数据库错误,将需要采取措施,尽量减少填写数据表格人员的转录或解释错误。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验