• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Analysis of arterial pulse propagation time variability for studying wave transmitting properties of arteries].

作者信息

Ueda K

机构信息

Department of Anesthesiology, Tottori University Faculty of Medicine, Yonago.

出版信息

Masui. 1995 Mar 3;44(3):388-95.

PMID:7745792
Abstract

Propagation time of arterial pulse waves was studied concerning intervals R-R and intervals of corresponding peaks of differential radial arterial pressure. These signals were detected by an ECG monitor LIFESCOPE 6 (NIHON KOHDEN) and a tonometric arterial pressure detector JENTOW 7700 (NIHON COLIN), and are simultaneously recorded by a data-recorder. The cyclic variations in arterial propagation time and heart rate fluctuations were analyzed by means of fast Fourier transform (FFT) using a personal computer PC-9801RX (NEC). Apparently, they resembled each other in their power spectra. Therefore, an index for assessment of wave transform characteristics was induced as follows: Magnitude of variation can be calculated by sigma(power x frequency) = sigma PF, where the power means a square root of amplitude of power spectrum by FFT. Then, sigma PFRR and sigma PFRP were defined as the variation in arterial pulse wave propagation time and variation in heart rate fluctuations, respectively. Furthermore, they were normalized by their mean values (mRR, mRP), respectively, as sigma PFRR was found proportionate to mRR. The components of low (0.05-0.075Hz) and mid (0.075-0.15Hz)-frequency bands of heart rate variability are considered from pressure-derived-fluctuation dependent on the vasomotor tone and the baroreceptor reflex of arteries. On the other hand, high frequency (0.15-0.45Hz) component of the heart rate fluctuation with respiratory cycle is decreased by arterial elasticity and is induced to propagation time variation directly. Therefore, (sigma PFRP.mRP-1)/(sigma PFRR.mRR-1) in high frequency band was proposed as an index for assessment of wave transform characteristics.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
[Analysis of arterial pulse propagation time variability for studying wave transmitting properties of arteries].
Masui. 1995 Mar 3;44(3):388-95.
2
[Decreasing heart rate and shortening of the arterial pulse propagation time by acupuncture in the spectral analyses].[针刺对心率及动脉脉搏传播时间的影响:频谱分析]
Masui. 1997 Feb;46(2):213-21.
3
The effects of metronome breathing on the variability of autonomic activity measurements.节拍器呼吸对自主神经活动测量变异性的影响。
J Manipulative Physiol Ther. 2000 Nov-Dec;23(9):610-4. doi: 10.1067/mmt.2000.110944.
4
Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms.从无创压力波形获得的动脉僵硬度的临床测量。
Am J Hypertens. 2005 Jan;18(1 Pt 2):3S-10S. doi: 10.1016/j.amjhyper.2004.10.009.
5
Large artery stiffness and pulse wave reflection: results of a population-based study.大动脉僵硬度与脉搏波反射:一项基于人群研究的结果
Blood Press. 2005;14(1):45-52. doi: 10.1080/08037050510008814.
6
Effects of spinal manipulative therapy on autonomic activity and the cardiovascular system: a case study using the electrocardiogram and arterial tonometry.脊柱推拿疗法对自主神经活动和心血管系统的影响:一项使用心电图和动脉张力测量法的案例研究。
J Manipulative Physiol Ther. 2000 Oct;23(8):545-50. doi: 10.1067/mmt.2000.109677.
7
Increased pulse-wave velocity in patients with anxiety: implications for autonomic dysfunction.焦虑症患者脉搏波速度增加:对自主神经功能障碍的影响。
J Psychosom Res. 2006 Jul;61(1):25-31. doi: 10.1016/j.jpsychores.2005.10.011.
8
[The automatic, beat-to-beat determination of the QT interval and analysis of its spontaneous variability under basal conditions].[QT间期的自动逐搏测定及其基础条件下自发变异性分析]
Rev Esp Cardiol. 1995 Nov;48(11):722-31.
9
Non-invasive in vivo assessment of changes in peripheral arterial properties with estimation of arterial volume compliance.通过估计动脉容积顺应性对周围动脉特性变化进行非侵入性体内评估。
Physiol Meas. 2007 Oct;28(10):1317-27. doi: 10.1088/0967-3334/28/10/015. Epub 2007 Sep 28.
10
Should one use electrocardiographic or Finapres-derived pulse intervals for calculation of cardiac baroreceptor sensitivity?应该使用心电图或无创血压监测仪得出的脉搏间期来计算心脏压力感受器敏感性吗?
Blood Press Monit. 1998 Oct;3(5):315-320.