Abstract

OBJECTIVE

Four commercially available enzyme-linked immunosorbent assays (ELISA) were evaluated for serological diagnosis of Helicobacter pylori (H. pylori) infection in 79 untreated patients.

METHODS

Infection has been diagnosed in 40 patients, in whom culture and/or urease test and histopathology from antral biopsies, were positive for H. pylori.

RESULTS

Sensitivity (Se) and specificity (Sp) of these tests, calculated with indeterminate serological results (9 patients) classified as positive (ind +) or negative (ind -), were not statistically different: GAP-test (Bio-Rad), Se = 95% (ind +), 90% (ind -), Sp = 84.6% (ind +), 89.7% (ind -); Pylori-Stat (Biowhittaker), Se = 97.5% (ind + or -), Sp = 71.8% (ind +), 71.9% (ind -); Premier H. pylori (Biomedical Diagnostics), Se = 92.5% (ind +), 90% (ind -), Sp = 84.6% (ind +), 81.2% (ind -); Cobas-Core (Roche), Se = 92.5% (ind + or -), Sp = 76.9% (ind +), 79.5% (ind -). There was a strong correlation between mucosal inflammation and H. pylori status. Discrepancies between infectious status and at least one serology result were observed in 16 patients (11 H. pylori negative and 5 H. pylori positive patients).

CONCLUSION

These 4 tests are of equivalent diagnostic value. Thus, the selection of one of them should take into account cost and practicability.

摘要

目的

对4种市售酶联免疫吸附测定(ELISA)方法进行评估,以用于79例未经治疗患者的幽门螺杆菌(H. pylori)感染的血清学诊断。

方法

40例患者已被诊断为感染,其胃窦活检组织的培养和/或尿素酶试验及组织病理学检查显示幽门螺杆菌呈阳性。

结果

将不确定的血清学结果(9例患者)分类为阳性(ind +)或阴性(ind -)后计算这些检测方法的敏感性(Se)和特异性(Sp),结果无统计学差异:GAP检测(伯乐公司),Se = 95%(ind +),90%(ind -),Sp = 84.6%(ind +),89.7%(ind -);幽门螺杆菌检测试剂盒(Biowhittaker公司),Se = 97.5%(ind +或 -),Sp = 71.8%(ind +),71.9%(ind -);幽门螺杆菌检测试剂盒(生物医学诊断公司),Se = 92.5%(ind +),90%(ind -),Sp = 84.6%(ind +),81.2%(ind -);Cobas - Core检测(罗氏公司),Se = 92.5%(ind +或 -),Sp = 76.9%(ind +),79.5%(ind -)。黏膜炎症与幽门螺杆菌状态之间存在强相关性。在16例患者(11例幽门螺杆菌阴性和5例幽门螺杆菌阳性患者)中观察到感染状态与至少一项血清学结果之间存在差异。

结论

这4种检测方法具有同等诊断价值。因此,选择其中一种应考虑成本和实用性。