Wataha J C, Hanks C T, Sun Z
Department of Prosthodontics, University of Michigan School of Dentistry, Ann Arbor 48109-1078, USA.
Dent Mater. 1994 May;10(3):156-61. doi: 10.1016/0109-5641(94)90025-6.
The choice of cell line for in vitro biological tests which assess the cytotoxicity of dental materials remains controversial, yet this issue is important because these tests are widely used to rate the biocompatibility of new and existing materials, and many different cell lines are commonly used. The purpose of the current study was to quantify the responses of four cell lines (Balb/c 3T3, L929, ROS 17/2.8 and WI-38) to 14 metal ions which are released from dental materials, and relate these responses to the metabolic activity and population doubling times of these cells.
Succinic dehydrogenase (SDH) activity was used to monitor metabolic activity and cytotoxic response.
The cell lines responded differently to most metal ions. In general, the Balb/c 3T3 line was the most sensitive, and the WI-38 line was the least sensitive. However, there were many exceptions depending on the metal ion. The passage number of the cells also affected the cytotoxic response. It was concluded that the cytotoxicity of materials which release metal ions will be significantly different depending on which cell line is selected and its passage number.
Based on the findings that cell lines ranked the toxicities of the metal ions similarly, it seems reasonable to use these types of in vitro tests to rank the cytotoxicities of materials. However, if these types of tests are used to predict in vivo cytotoxicity, care should be taken to choose conditions and cells which are relevant.
用于评估牙科材料细胞毒性的体外生物学测试所选用的细胞系仍存在争议,但这个问题很重要,因为这些测试被广泛用于评定新材料和现有材料的生物相容性,并且常用许多不同的细胞系。本研究的目的是量化四种细胞系(Balb/c 3T3、L929、ROS 17/2.8和WI-38)对牙科材料释放的14种金属离子的反应,并将这些反应与这些细胞的代谢活性和群体倍增时间联系起来。
使用琥珀酸脱氢酶(SDH)活性来监测代谢活性和细胞毒性反应。
各细胞系对大多数金属离子的反应不同。一般来说,Balb/c 3T3细胞系最敏感,WI-38细胞系最不敏感。然而,根据金属离子的不同有许多例外情况。细胞的传代次数也会影响细胞毒性反应。得出的结论是,释放金属离子的材料的细胞毒性会因所选细胞系及其传代次数的不同而有显著差异。
基于细胞系对金属离子毒性的排名相似这一发现,使用这类体外测试来对材料的细胞毒性进行排名似乎是合理的。然而,如果使用这类测试来预测体内细胞毒性,应注意选择相关的条件和细胞。