4特斯拉下基于血氧水平依赖性功能磁共振成像包括毛细血管床的贡献:回波平面成像与先前使用内在信号的光学成像相关。

BOLD based functional MRI at 4 Tesla includes a capillary bed contribution: echo-planar imaging correlates with previous optical imaging using intrinsic signals.

作者信息

Menon R S, Ogawa S, Hu X, Strupp J P, Anderson P, Uğurbil K

机构信息

John P. Robarts Research Institute, Advanced Imaging Group, London, Ontario, Canada.

出版信息

Magn Reson Med. 1995 Mar;33(3):453-9. doi: 10.1002/mrm.1910330323.

Abstract

We show that the EPI time course in functional MR imaging at 4 Tesla displays a multiphasic response in response to photic stimulation. Focal areas of gray matter display an initial negative change in signal intensity that reaches a maximum of 1% about 2 s after the onset of photic stimulation. This component then changes sign, reaching a positive maximum about 5 s after the onset of the stimulus. Other areas, including those where draining veins are visible, show only a positive signal change, reaching a maximum of about 6% after the onset of the visual stimulus. These time constants are in very good agreement with published data obtained with intrinsic optical mapping techniques, where a deoxygenation phase has been shown to occur in functionally specific cortical columns, followed by an increase in blood volume which is more distributed in nature. Thus, we believe there is strong evidence that a sensitivity to capillary oxygenation state is present in high S/N functional MR images obtained with EPI at 4 T.

摘要

我们表明,在4特斯拉的功能磁共振成像中,回波平面成像(EPI)时间进程对光刺激显示出多相反应。灰质的焦点区域在光刺激开始后约2秒显示信号强度的初始负变化,达到最大值1%。然后该成分改变符号,在刺激开始后约5秒达到正最大值。其他区域,包括可见引流静脉的区域,仅显示正信号变化,在视觉刺激开始后达到最大值约6%。这些时间常数与使用内在光学映射技术获得的已发表数据非常吻合,在该技术中,已表明在功能特异性皮质柱中会发生脱氧阶段,随后是血容量增加,而血容量增加在性质上分布更广泛。因此,我们认为有强有力的证据表明,在4T下用EPI获得的高信噪比功能磁共振图像中存在对毛细血管氧合状态的敏感性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验