Abstract

UNLABELLED

We compared TcN-NOET [bis(N-ethoxy, N-ethyl dithiocarbamato)nitrido 99mTc] and 201Tl images to estimate the utility of this compound in the detection of coronary artery disease (CAD).

METHODS

Twenty-five patients undergoing cardiac catheterization had stress-redistribution-reinjection 201Tl SPECT imaging, stress-delayed (2, 4 and 6 hr postinjection) and rest-delayed (4 hr postinjection) TcN-NOET SPECT imaging.

RESULTS

Nineteen patients had coronary stenosis > or = 50% and six were normal. Stress TcN-NOET and 201Tl imaging were concordant for the presence of CAD in 22/25 patients (88%, kappa = 0.76 +/- 0.20). The overall sensitivity of TcN-NOET SPECT imaging was 74% (14/19 patients) and 68% (13/19 patients) for 201Tl SPECT imaging. The specificity was 100% (6/6 patients) for both techniques. The overall agreement of TcN-NOET and 201Tl for the presence of disease in individual coronary arteries was 96% (72/75 arteries, kappa = 0.92 +/- 0.16). Segmental analysis of stress images showed a concordance in 211/225 segments (94%, kappa = 0.82 +/- 0.09). Comparison of the 4-hr images showed a concordance between 201Tl and TcN-NOET in 21/23 patients. Following TcN-NOET injection at rest, seven patients had a defect on the initial images, which had normalized 4 hr postinjection in four patients (57%).

CONCLUSION

Perfusion imaging with TcN-NOET and 201Tl gives comparable diagnostic information in patients undergoing exercise testing for assessment of CAD. Because of the normalization of myocardial activity 4 hr after injection in some patients, we conclude that TcN-NOET is a potential technetium compound equivalent to 201Tl.

摘要

未标注

我们比较了TcN-NOET[双(N-乙氧基,N-乙基二硫代氨基甲酰基)氮99m锝]和201铊图像,以评估该化合物在检测冠状动脉疾病(CAD)中的效用。

方法

25例接受心脏导管检查的患者进行了静息-再分布-再注射201铊单光子发射计算机断层显像(SPECT)成像、负荷延迟(注射后2、4和6小时)及静息延迟(注射后4小时)TcN-NOET SPECT成像。

结果

19例患者冠状动脉狭窄≥50%,6例正常。负荷TcN-NOET和201铊成像在22/25例患者(88%,kappa=0.76±0.20)中对CAD的存在情况一致。TcN-NOET SPECT成像的总体敏感性为74%(14/19例患者),201铊SPECT成像为68%(13/19例患者)。两种技术的特异性均为100%(6/6例患者)。TcN-NOET和201铊对各冠状动脉疾病存在情况的总体一致性为96%(72/75支动脉,kappa=0.92±0.16)。负荷图像的节段分析显示211/225个节段一致(94%,kappa=0.82±0.09)。4小时图像的比较显示21/23例患者中201铊和TcN-NOET一致。静息注射TcN-NOET后,7例患者初始图像有缺损,其中4例(57%)在注射后4小时恢复正常。

结论

在接受运动试验以评估CAD的患者中,TcN-NOET和201铊灌注成像提供了可比的诊断信息。由于部分患者注射后4小时心肌活性恢复正常,我们得出结论,TcN-NOET是一种等同于201铊的潜在锝化合物。