Reda Z, Houri S, Davis A L, Baum V C
Department of Pediatrics, University of California, Los Angeles, USA.
J Pediatr. 1995 Jun;126(6):961-5. doi: 10.1016/s0022-3476(95)70223-7.
We evaluated the effect of elevated airway pressure on the validity of intravascular pressure obtained in the distal inferior vena cava (IVC) as a measure of central venous pressure (CVP) in a group of children receiving mechanical ventilation. The IVC pressure correlated well with CVP in the patients without abdominal distention, but the disparity was wider in those with abdominal distention. Elevated mean airway pressure or positive end-expiratory pressure had no effect on the relationship of IVC to CVP.
我们评估了气道压力升高对一组接受机械通气儿童的下腔静脉远端血管内压力作为中心静脉压(CVP)测量指标有效性的影响。在无腹胀的患者中,下腔静脉压力与中心静脉压相关性良好,但在有腹胀的患者中差异更大。平均气道压力升高或呼气末正压对下腔静脉与中心静脉压的关系无影响。