Suppr超能文献

Accuracy of central venous pressure measurement from the abdominal inferior vena cava.

作者信息

Lloyd T R, Donnerstein R L, Berg R A

机构信息

University Heart Center, Steele Memorial Children's Research Center, University of Arizona College of Medicine, Tucson.

出版信息

Pediatrics. 1992 Mar;89(3):506-8.

PMID:1741229
Abstract

Central venous pressure measurements in the abdominal inferior vena cava were compared with measurements in the right atrium in 10 infants and 10 children during cardiac catheterization. At end expiration, the mean pressures at these two sites were within 1 mm Hg of each other in all 20 patients, with a mean difference of 0.0 +/- 0.36 mm Hg. The abdominal inferior vena cava is a safe and convenient site for measurement of central venous pressure, and our study confirms that such measurements are accurate.