This study assessed the postoperative microvascular hemodynamics in end-to-side arterial anastomoses of varied angles in order to determine whether the angle of the anastomosis affects arterial flow. Thirty male rats were divided into three groups of ten. Carotid to carotid end-to-side anastomoses were performed with anastomotic angles of 45, 90, and 135 degrees. Postoperative flow was assessed using high frequency pulsed Doppler ultrasound (HFPDU) at 30 and 120 min postoperatively. Measurements at 30 min demonstrated significant differences in flow, with the 45 degrees grafted vessels utilizing 56.5% of total carotid flow, and the 90 degrees and 135 degrees anastomoses appropriating 46.5% and 43.2% of flow, respectively (comparing 45 degrees to both 90 degrees, P < 0.05, and 135 degrees, P < 0.002). The change from baseline in 45 degrees and 90 degrees groups dissipated over a 2 hr postoperative period, but flow in the grafted vessels in the 135 degrees group continued well below 50% at 39.9% (comparing to both 45 degrees and 90 degrees, P < 0.001), thereby displaying a significant difference in the postoperative arterial flow of varied angled microanastomoses.
本研究评估了不同角度的端侧动脉吻合术后的微血管血流动力学,以确定吻合角度是否影响动脉血流。30只雄性大鼠被分为三组,每组10只。进行了颈动脉到颈动脉的端侧吻合,吻合角度分别为45度、90度和135度。术后30分钟和120分钟使用高频脉冲多普勒超声(HFPDU)评估血流。30分钟时的测量结果显示血流存在显著差异,45度移植血管利用了总颈动脉血流的56.5%,90度和135度吻合分别占血流的46.5%和43.2%(45度与90度比较,P < 0.05;45度与135度比较,P < 0.002)。45度和90度组相对于基线的变化在术后2小时内消失,但135度组移植血管的血流在术后39.9%时仍远低于50%(与45度和90度组比较,P < 0.001),从而显示出不同角度微血管吻合术后动脉血流存在显著差异。