Research protocols often utilize serial exercise testing to examine the efficacy of anti-ischemic therapies. These tests, however, are prone to multiple sources of bias. This investigation sought to determine the influence of varying precordial electrocardiographic (ECG) electrode placement on the detection of exercise-induced ST-segment shifts. Fifteen coronary artery disease patients with abnormal exercise tests were studied. Based on the previous exercise test, the precordial electrode position exhibiting the greatest ST-segment shift was selected as the reference electrode. Four additional electrodes were placed around this reference electrode and exercise testing was performed. ECG strips were recorded every minute. The time-to-onset and -offset of ischemic-type ST-segment depression was recorded. ST-segment depression was recorded during exercise from the reference electrode in 12 of 15 patients. Ischemic-type ST-depression was also recorded in each of these 12 patients with the surrounding electrodes; however, the time-to-onset detected by all four surrounding electrodes concurred in only 5 of 12 (42%) patients. The time-to-offset of the ST-segment depression concurred in 9 of 12 (75%) patients. Serial ECGs recorded from similar but not exactly the same precordial ECG electrode position should yield similar results for the detection of ischemia, but time-to-onset or -offset of ischemia may differ by 60 s or more. Small changes in the time-to-onset and -offset of ischemia should not be considered reliable indicators of anti-ischemia efficacy.

摘要

研究方案常常采用系列运动试验来检验抗缺血治疗的疗效。然而,这些试验容易受到多种偏倚来源的影响。本研究旨在确定胸前区心电图(ECG)电极放置位置的变化对运动诱发ST段移位检测的影响。对15例运动试验异常的冠心病患者进行了研究。根据之前的运动试验,选择ST段移位最大的胸前区电极位置作为参考电极。在该参考电极周围再放置四个电极,然后进行运动试验。每分钟记录心电图条带。记录缺血型ST段压低的起始时间和结束时间。15例患者中有12例在运动期间从参考电极记录到ST段压低。这12例患者使用周围电极时也记录到了缺血型ST段压低;然而,在这12例患者中,所有四个周围电极检测到的起始时间仅在5例(42%)患者中一致。ST段压低的结束时间在12例患者中的9例(75%)中一致。从相似但不完全相同的胸前区心电图电极位置记录的系列心电图对于缺血检测应产生相似的结果,但缺血的起始时间或结束时间可能相差60秒或更长时间。缺血起始时间和结束时间的微小变化不应被视为抗缺血疗效的可靠指标。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验