Margolis R H, Rieks D, Fournier E M, Levine S E
Department of Otolaryngology, University of Minnesota, Minneapolis.
Arch Otolaryngol Head Neck Surg. 1995 Jan;121(1):44-55. doi: 10.1001/archotol.1995.01890010032007.
Tympanic electrocochleography (ECOG) is a noninvasive technique for recording cochlear potentials with an electrode placed on the tympanic membrane. Electrocochleography is used clinically in the evaluation of patients for endolymphatic hydrops. This study was undertaken to obtain normative data for ECOG responses to clicks and tone bursts and to determine clinical indicators that result in high test specificities.
Three cochlear potentials were measured; the eighth nerve compound action potential, the cochlear microphonic, and the summating potential. The subjects were 53 normal hearing adults with negative histories for symptoms of Menière's disease. The ECOG responses were measured with a silver wire-rayon wick electrode that was placed on the tympanic membrane under direct microscopic visualization. Stimuli were condensation, rarefaction, and alternating polarity clicks and 1- and 2-kHz tone bursts.
Measures that appear to be useful in the evaluation of endolymphatic hydrops include the summating potential to action potential ratio, action potential latency difference to condensation and rarefaction clicks, and the tone-burst-evoked summating potential. Relationships among these measures were investigated, and abnormal criteria were determined that result in test specificities of 95%.
Menière's disease is viewed as a progressive disease in which ECOG characteristics vary with the disease state. Cases are presented to illustrate ECOG responses in various stages of the disease. The normative data presented in this article are useful for the detection of Menière's disease in its early stages.
鼓室电耳蜗图(ECOG)是一种通过将电极置于鼓膜上记录耳蜗电位的非侵入性技术。电耳蜗图在临床上用于评估内淋巴积水患者。本研究旨在获取对短声和短纯音的ECOG反应的正常数据,并确定能产生高检测特异性的临床指标。
测量三种耳蜗电位;第八神经复合动作电位、耳蜗微音电位和总和电位。受试者为53名听力正常、无梅尼埃病症状病史的成年人。ECOG反应通过在直接显微镜观察下置于鼓膜上的银丝 - 人造纤维灯芯电极进行测量。刺激声为压缩、稀疏和交替极性短声以及1千赫和2千赫短纯音。
在评估内淋巴积水方面似乎有用的测量指标包括总和电位与动作电位比值、压缩和稀疏短声的动作电位潜伏期差异以及短纯音诱发的总和电位。研究了这些测量指标之间的关系,并确定了能产生95%检测特异性的异常标准。
梅尼埃病被视为一种进行性疾病,其中ECOG特征随疾病状态而变化。文中展示了病例以说明该疾病不同阶段的ECOG反应。本文给出的正常数据有助于早期检测梅尼埃病。