非对称兆伏级射束的相对输出因子

Relative output factors of asymmetric megavoltage beams.

作者信息

Tenhunen M, Lahtinen T

机构信息

Department of Radiotherapy and Oncology, Kuopio University Hospital, Finland.

出版信息

Radiother Oncol. 1994 Sep;32(3):226-31. doi: 10.1016/0167-8140(94)90022-1.

Abstract

A new method for calculating output factors of asymmetric therapy fields is presented. The method uses the output factors of symmetric fields, as well as off-axis ratios measured in air, to calculate the output factor for an arbitrary asymmetric field. Calculations have been checked by measurements in four photon beams (4-18 MV) of three different linear accelerators. The accuracy between the theory and the measurements is generally better than 1%. According to the preliminary results the method may also be suitable for megavoltage electron beams.

摘要

提出了一种计算非对称治疗射野输出因子的新方法。该方法利用对称射野的输出因子以及在空气中测量的离轴比,来计算任意非对称射野的输出因子。已通过在三台不同直线加速器的四束光子束(4 - 18MV)中进行测量来检验计算结果。理论与测量之间的精度通常优于1%。根据初步结果,该方法可能也适用于兆伏级电子束。