[自体静脉移植物内皮细胞的扫描电镜图像分析]

[SEM image analysis of endothelial cells of autogenous vein grafts].

作者信息

Qian J X, Huang Y T, Bao C J

机构信息

514 Hospital, Beijing.

出版信息

Zhonghua Wai Ke Za Zhi. 1994 Mar;32(3):147-9.

PMID:7842902
Abstract

The autogenous veins of 17 dogs were distended with 40kPa, 80kPa and 120kPa pressure prior to grafting to femoral arteries respectively. The sections were harvested immediately, and after 1 week, 4 and 16 weeks and inspected with SEM. The endothelial cells of grafted veins were studied with an image analysis system. The results showed that the desquamation extent of intimal layer correlated positively with pressure. 80 and 120kPa caused relatively severe damage to the endothelium, which was significantly different from that of control group (P < 0.05). We conclude that preimplantation distention of vein grafts should be employed with less than 80kPa pressure, and 120kPa can never be used in clinic, as it adversely affects the course of reendotheli alization. The distention did not make a notable impact to graft patency rate as demonstrated in this experiment.

摘要

分别在移植至股动脉前,以40kPa、80kPa和120kPa的压力扩张17只犬的自体静脉。立即取材,以及在1周、4周和16周后取材,并用扫描电子显微镜检查。用图像分析系统研究移植静脉的内皮细胞。结果表明,内膜层的剥脱程度与压力呈正相关。80kPa和120kPa对内皮造成相对严重的损伤,与对照组相比差异有统计学意义(P<0.05)。我们得出结论,静脉移植物植入前扩张应采用低于80kPa的压力,120kPa绝对不能用于临床,因为它会对再内皮化过程产生不利影响。如本实验所示,扩张对移植物通畅率没有显著影响。