Suppr超能文献

接触式经巩膜钕:钇铝石榴石激光睫状体光凝术的变异性

Variability of contact transscleral neodymium:YAG cyclophotocoagulation.

作者信息

Echelman D A, Stern R A, Shields S R, Simmons R B, Shields M B

机构信息

Joseph M. Bryan Glaucoma Clinic, Duke University Eye Center, Durham, North Carolina 27710.

出版信息

Invest Ophthalmol Vis Sci. 1995 Feb;36(2):497-502.

PMID:7843918
Abstract

PURPOSE

To study the variability of ciliary body lesions created by contact Nd:YAG cyclophotocoagulation and to evaluate modifications in probe design to reduce this variability.

METHODS

Contact transscleral Nd:YAG cyclophotocoagulation was performed on fresh, enucleated porcine eyes in three ways: using a standard, handheld fiber-optic probe (98 eyes); using the same probe with an adjunctive contact lens guide to control for probe pressure, angle, and position (69 eyes); and using a spring-loaded handpiece to control for probe pressure (148 eyes). Four laser lesions were created in each eye and were rated for size and severity of tissue response.

RESULTS

For the three groups of eyes, the mean for size differences (largest lesion minus smallest lesion in millimeters for each eye) was 2.53, 1.65, and 2.36, respectively. The mean for severity differences (most severe lesions minus least severe lesion for each eye, based on a four-part subjective rating) was 1.9, 1.1, and 1.7, respectively. These measures of size difference and severity difference were significantly lower with the lens guide than with the other two systems (P = 0.022 and P = 0.020, respectively).

CONCLUSIONS

These findings indicate that contact transscleral cyclophotocoagulation can be associated with considerable variation in the size and severity of the ciliary body reaction. This variation has a significant dependence on probe pressure and orientation against the eye and can be reduced by modification in probe design.

摘要

目的

研究接触式Nd:YAG睫状体光凝术造成的睫状体病变的变异性,并评估探头设计的改进以减少这种变异性。

方法

对新鲜摘除的猪眼进行接触式经巩膜Nd:YAG睫状体光凝术,采用三种方式:使用标准手持光纤探头(98只眼);使用相同探头并辅以接触镜导向装置以控制探头压力、角度和位置(69只眼);使用弹簧加载手持件以控制探头压力(148只眼)。每只眼制作四个激光损伤,并对组织反应的大小和严重程度进行评分。

结果

对于三组眼睛,大小差异的平均值(每只眼最大损伤减去最小损伤,单位为毫米)分别为2.53、1.65和2.36。严重程度差异的平均值(基于四分主观评分,每只眼最严重损伤减去最不严重损伤)分别为1.9、1.1和1.7。使用镜片导向装置时,这些大小差异和严重程度差异的测量值明显低于其他两个系统(分别为P = 0.022和P = 0.020)。

结论

这些发现表明,接触式经巩膜睫状体光凝术可能与睫状体反应的大小和严重程度存在相当大的变异性有关。这种变异性很大程度上取决于探头对眼睛的压力和方向,通过改进探头设计可以降低这种变异性。

相似文献

引用本文的文献

2
Real-time control for transscleral cyclophotocoagulation.经巩膜睫状体光凝术的实时控制
Graefes Arch Clin Exp Ophthalmol. 1997 Dec;235(12):794-801. doi: 10.1007/BF02332865.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索