Accuracy, alarm limits and rise times of 12 oxygen analysers.

作者信息

Lauber R, Steiner A, Zbinden A M

机构信息

Research Section, University Hospital of Berne, Switzerland.

出版信息

Anaesthesia. 1994 Dec;49(12):1071-7. doi: 10.1111/j.1365-2044.1994.tb04359.x.

DOI:10.1111/j.1365-2044.1994.tb04359.x
PMID:7864324
Abstract

The Comité Européen de Normalisation recently proposed a new standard for 'the particular requirements of oxygen monitors for medical use'. The feasibility of this proposed standard was tested in respect of (1) accuracy of alarm activation (2) accuracy of oxygen display value during both continuous and cyclical gas flows (3) rise time during rapid changes in oxygen concentration in the following 12 analysers: Datex Capnomac II and Servomex 570A (paramagnetic); Brüel & Kjaer 1304 (magnetoacoustic); Criticare Poet II, Multinex, Dräger Oxydig, Dräger PM 8030, Megamed 046A (part of the Megamed 700 ventilator), Ohmeda 5120, Spacelabs Multigas, Teledyne TED 200 (galvanic); Kontron OM 810 (polarographic). All the analysers tested displayed an oxygen reading which was within +/- 3 vol% of the actual oxygen concentrations of the test gases (15, 21, 40, 60 and 100 vol%). A cyclical pressure of between -1.5 to +8 kPa did not affect the measured oxygen concentration as displayed by the Brüel & Kjaer 1304, Datex Capnomac II and Servomex 570A analysers. The remainder, however, showed, depending on their measuring principle, a display error of between -1 and +6 vol%. After exposure to high pressure all the oximeters functioned normally. Some of the tested devices showed more than 2% of deviation between their alarm activation and the preset alarm limits. Only the Kontron OM 810, the Megamed 046A and the Spacelabs Multigas monitors satisfied the requirements at all the tested oxygen concentrations. The time required by the oxygen analyser to display the rise from 29 to 92 vol % after a sudden change of concentration from 21 to 100 vol % O2 is defined as "rise time" and must not, according to the Comité Européen de Normalisation standard proposal, exceed the manufacturers' specification by more than a factor of 1.15.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Accuracy, alarm limits and rise times of 12 oxygen analysers.
Anaesthesia. 1994 Dec;49(12):1071-7. doi: 10.1111/j.1365-2044.1994.tb04359.x.
2
Carbon dioxide analysers: accuracy, alarm limits and effects of interfering gases.二氧化碳分析仪:准确性、警报限值及干扰气体的影响
Can J Anaesth. 1995 Jul;42(7):643-56. doi: 10.1007/BF03011887.
3
Accuracy and cross-sensitivity of 10 different anesthetic gas monitors.10种不同麻醉气体监测仪的准确性和交叉敏感性。
J Clin Monit. 1993 Nov;9(5):364-73. doi: 10.1007/BF01618679.
4
Resistance, reverse flow and opening pressure of unidirectional valves.单向阀的阻力、逆流和开启压力。
Anaesthesia. 1995 Dec;50(12):1065-9. doi: 10.1111/j.1365-2044.1995.tb05953.x.
5
[Inspiratory and expiratory resistance of 8 semi-closed circle systems].[8个半封闭式环路系统的吸气和呼气阻力]
Anaesthesist. 1991 Aug;40(8):441-5.
6
Evaluation of three transportable multigas anesthetic monitors: the Bruel & Kjaer Anesthetic Gas Monitor 1304, the Datex Capnomac Ultima, and the Nellcor N-2500.三款便携式多气体麻醉监测仪的评估:Bruel & Kjaer麻醉气体监测仪1304、Datex Capnomac Ultima和Nellcor N - 2500。
J Clin Monit. 1993 Apr;9(2):91-8. doi: 10.1007/BF01616920.
7
[Checking the precision of capnometers].[检查二氧化碳监测仪的精度]
Anasthesiol Intensivmed Notfallmed Schmerzther. 1992 Feb;27(1):42-50. doi: 10.1055/s-2007-1000250.
8
The Ohmeda Rascal II. A new gas analyser for anaesthetic use.
Anaesthesia. 1994 Jan;49(1):44-53. doi: 10.1111/j.1365-2044.1994.tb03313.x.
9
An evaluation of fourteen oxygen analysers for use in patient breathing circuits.
Anaesth Intensive Care. 1986 Nov;14(4):431-6. doi: 10.1177/0310057X8601400418.
10
[Capnometry in emergency air transport--experimental studies of the accuracy of 3 CO2 analyzers in the hypobaric chamber].
Anasthesiol Intensivmed Notfallmed Schmerzther. 1994 Dec;29(8):487-91. doi: 10.1055/s-2007-996789.