A rapid ELISA for measurement of anti-glomerular basement membrane antibodies using microwaves.

作者信息

van Dorp R, Daha M R, Muizert Y, Marani E, Boon M E

机构信息

Leiden Cytology and Pathology Laboratory, The Netherlands.

出版信息

J Clin Lab Immunol. 1993;40(3):135-47.

PMID:7877153
Abstract

The presence of anti-glomerular basement membrane antibodies is one of the features of Goodpasture's syndrome. Since the disease has a rapidly progressive course, an early diagnosis is essential. As was already demonstrated in other ELISA methods, 2.45-GHz microwave irradiation can accelerate all kinds of time consuming processes in several laboratory techniques. The application of microwaves in an ELISA for the measurement of anti-GBM antibodies in serum indicated that a considerable time reduction of 75% can be achieved, resulting in a rapid and reliable assay. In addition, microwaves can also have a positive effect on the resolution of that particular ELISA as shown in this study.