Suppr超能文献

Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients.

作者信息

Job F P, Ringelstein E B, Grafen Y, Flachskampf F A, Doherty C, Stockmanns A, Hanrath P

机构信息

Medical Clinic I, Rheinisch-Westfälischen Technischen Hochschule, Aächen, Germany.

出版信息

Am J Cardiol. 1994 Aug 15;74(4):381-4. doi: 10.1016/0002-9149(94)90407-3.

Abstract

The prevalence of a patent foramen ovale was assessed by simultaneously performing transesophageal contrast echocardiography and transcranial contrast Doppler sonography (TCD) in 137 subjects (mean age 36 years) with stroke of unclarified etiology (n = 41), clarified etiology (n = 33), and in normal subjects (n = 63; mean age 32 years). Patent foramen ovale was found significantly more often in patients with unclarified than clarified strokes or in normal subjects (66% vs 33%, or 43%). Massive paradoxical embolism through a patent foramen ovale, identified by TCD, occurred significantly (p < 0.01) more often in patients with unclarified (64%) than clarified (27%) strokes or in normal subjects (3%). However, minimal shunts were typical in normal subjects (79%). Patent foramen ovale was detected indirectly by TCD when calculated on the basis of transesophageal contrast echocardiographic findings (sensitivity 89%, specificity 92%). Thus, TCD reliably detects paradoxical cerebral embolism through a patent foramen ovale, and provides important additional information for evaluating its clinical relevance by semi-quantification of embolic contrast material.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验