Taylor A, Clark S, Ball T
Department of Radiology, Emory University Medical Center, Egleston Children's Hospital, Atlanta, Georgia.
Clin Nucl Med. 1994 Jul;19(7):575-80. doi: 10.1097/00003072-199407000-00002.
Tc-99m MAG3 scans were obtained in two neonates in whom previous Tc-99m DTPA scans had been interpreted as showing possible obstruction. In both patients, Tc-99m MAG3 provided superior diagnostic images and allowed obstruction to be excluded. The favorable dosimetry of MAG3, coupled with the fact that its clearance is two to three times higher than that of DTPA, makes MAG3 an excellent radiopharmaceutical for pediatric patients, particularly in those patients with impaired renal function and possible obstruction.
对两名新生儿进行了锝-99m巯基乙酰三甘氨酸(Tc-99m MAG3)扫描,之前对这两名新生儿的锝-99m二乙三胺五乙酸(Tc-99m DTPA)扫描结果被解读为可能存在梗阻。在这两名患者中,Tc-99m MAG3均提供了更优质的诊断图像,并排除了梗阻。MAG3良好的剂量学特性,再加上其清除率比DTPA高两到三倍,使得MAG3成为儿科患者的一种优秀放射性药物,尤其是对于那些肾功能受损且可能存在梗阻的患者。