Murakawa K, Noma K, Ishida K, Matsuda M, Terashita K, Maeda S, Izumi R
Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya.
Masui. 1994 Jul;43(7):998-1003.
A comparative study of the circulatory effects of stellate ganglion block (SGB) and high thoracic epidural block (TEB) was conducted in 11 patients. Although blood pressure and heart rate showed no significant changes even after SGB, they both decreased significantly following TEB. The blood flow in the common carotid artery (CCA) increased markedly at 5 minutes after performing SGB, and at 20 minutes it reached its peak value of 163.5 +/- 7.8%, and the increase remained significant up to 75 minutes. On the other hand, it increased significantly from 5 minutes after performing TEB and reached its peak of 122.2 +/- 7.6% at 15 minutes, and this increase remained significant up to 60 minutes. In comparing these two nerve blocks, the blood flow in the CCA showed a more marked increase following SGB than after TEB from 5 to 60 minutes after performing. The blood flow rate in the CCA increased markedly from 5 minutes after performing SGB, reached its peak of 139.1 +/- 11.3% at 20 minutes, and this increase remained significant up to 60 minutes thereafter. After performing TEB no significant changes were observed. In comparing SGB and TEB, from 5 to 60 minutes after performing, the rate became markedly faster after SGB than after TEB. The vascular diameter of the CCA from 5 minutes after performing SGB showed a slight but significant enlargement, and at 20 minutes it reached its maximum of 111.7 +/- 3.0%, and this significant enlargement persisted up to 60 minutes. From 10 minutes after performing TEB, it showed a slight but significant enlargement.(ABSTRACT TRUNCATED AT 250 WORDS)
对11例患者进行了星状神经节阻滞(SGB)和高位胸段硬膜外阻滞(TEB)循环效应的比较研究。尽管SGB后血压和心率即使在术后也无显著变化,但TEB后两者均显著下降。实施SGB后5分钟,颈总动脉(CCA)血流明显增加,20分钟时达到峰值163.5±7.8%,且这种增加在75分钟内一直显著。另一方面,TEB后5分钟血流显著增加,15分钟时达到峰值122.2±7.6%,且这种增加在60分钟内一直显著。在比较这两种神经阻滞时,实施后5至60分钟内,SGB后CCA血流增加比TEB后更显著。实施SGB后5分钟CCA血流速度明显增加,20分钟时达到峰值139.1±11.3%,此后这种增加在60分钟内一直显著。实施TEB后未观察到显著变化。在比较SGB和TEB时,实施后5至60分钟内,SGB后血流速度比TEB后明显加快。实施SGB后5分钟CCA血管直径有轻微但显著的增大,20分钟时达到最大值111.7±3.0%,且这种显著增大持续到60分钟。实施TEB后10分钟开始,血管直径有轻微但显著的增大。(摘要截断于250字)